Chapter 5: Menu reference 
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual  249 
This is a setting for panel only. For expanders, see “2.2.2.n.4.5 EOL” on page 
152. 
8.6.3 Siren tamper EOL 
 
The Siren tamper end of line resistor menu allows you to define an end-of-line 
resistor value for the siren. The available values are the same as in “8.6.2 EOL” 
on page 248. 
8.6.4 Swinger shunt 
 
The Swinger shunt value defines the number of alarms from a zone until it is 
shunted. The default value is 2, the maximum number is 4. 
This zone must have the “4.1.n.6.6 Swinger shunt” option enabled (see 
page 174). 
8.6.5 Report restore 
 
If the Report restore option is set to On ACK, the restore event is reported to the 
central station when a user acknowledges an alarm.  
If the option is set to On input close, the restore event is reported when the zone 
returns to the normal state. 
8.7 Panel and AB options 
 
The Panel and AB options menu allows you to change particular system values. 
See also “Initial start-up” on page 114. 
If particular settings are changed in this menu, you are prompted to confirm those 
changes while trying to leave this menu. See “Confirmation of changes” on 
page 111. 
8.7.1 Panel name 
 
The Panel name menu lets you change the panel name.