Chapter 5: Menu reference 
256  Advisor Advanced ATSx500A(-IP) Installation and Programming Manual 
8.8.8 Mon 3 HC out 
  
Monitor 3rd high current output option defines whether high current output 3 is 
monitored or not. 
Output 3 mode depends on the panel model. See “Outputs” on page 30 for 
details. 
8.8.9 Card number 
 
Select the way the card number is represented in the control panel. 
•  Basic. The card number is represented in the standard Advisor Advanced 
format.   
•  Titan. The card number is represented in the extended Titan format.  
8.8.10 Anonymize Log 
 
The menu allows you to set a time period, after which the user details are 
removed from a log entry.  
The allowed range is 0 to 60 days, 0 means the functionality is disabled. The 
default value is 30 days. 
8.9 Timed Unset / ATM 
 
The menu allows you to configure the ATM (automated teller machine) interface. 
8.9.1 Delay 
 
The option value is the time between the first and the second ATM user code 
entering. At the end of the programmed delay period the ATM user is be 
prompted to re-enter the code. 
The allowed range is 0 to 15 minutes. 0 means that the ATM user code can be 
entered twice without any delay. The default value is 0.