Appendix A: Advisor Advanced events
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual 325
Group
#
Event description
Notes
Other
1
Area disarmed
Area disarmed (16 events, 1 per
area)
2
Area alarm
Zones in alarm in area (16
events, 1 per area)
3
DGP outputs
System output assigned to this
DGP is active (16 events, 1 per
outputs). First 16 on DGP can
also be activated by physical
output function
4
Zones
Zone on this DGP active (16
events, 1 per zone)
5
Physical outputs
Output connected to this DGP is
active (255 events, 1 per
output). Outputs above 16 are
only activated by door macro.
6
Door controller
battery test active
The battery test on this door
controller is running
7
Door controller
battery test fail
The battery test failed on this
door controller
8
Door controller
siren active
The siren output (16th relay) is
active