Chapter 3: System functions
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual 75
3. In menu “6.1.n.2 Formula” program the condition filter as below:
#
Event or operand
Description
1>
Keypad.1.7
Correct PIN, entered on keypad 1.
2
OR
3
Zone.10.1
Active Zone 10, which is connected to the key switch and set up
in “4 Zones and areas” menu.
4
AND
5
Area.1.3
Area 1 unset.
4. In menu “6.2 Outputson page 219 set the following values:
- Select filter “Door open” for output 10. Output 10 can then be used to unlock
a door.
- Select Pulsed mode.
- Set Delay time to 00:00’00.
- Set Active time to 00:00’05 s.