8
2SHQ 
  3
U
contains the following information.
This screen shows an opening of Partition 3 on September 25
th
at 5:27 p.m. by user 75. The
[
7
] shows that this event is not programmed to be reported to the central monitoring station.
POSSIBLE LOG MESSAGES
DISPLAY
DESCRIPTION
TXlobat
Transmitter Low Battery - The transmitter has a low battery.
ZN Lost
Zone Lost - A wireless or multiplexed zone device is not reporting to
the control.
Duress
Duress - The control has been armed or disarmed with a Duress
code.
Man Fire
Manual Fire - Keypad “Fire” has been activated.
Aux 2
Auxiliary 2 - Keypad “Medical” has been activated.
Panic
Panic - Keypad “Panic” has been activated.
KP Tamper
Keypad Tamper - The keypad tamper has been activated.
BoxTamp
Box Tamper - The box tamper circuit has been activated.
AC Fail
AC Fail - AC failure has been detected.
OverCur
Over Current - A short circuit of a power supply has occurred.
Srn Tamp
Siren Tamper - A siren or speaker tamper has been detected.
Tel Flt
Telephone Fault - A telephone fault or tamper has been detected.
Exp Trb
Expansion Trouble - An expansion device or keypad is not reporting
to the control.
Log Full
Log Full - The event log is full.
Open
Open - Reports user number, date, time and partition of opening .
Close
Close - Reports user number, date, time and partition of closing.
Exit Err
Exit Error - Entry/Exit zone was faulted at the instant the exit delay
expired.
Rec Close
Recent Close - An alarm occurred within 5 minutes after the control
was armed.
Autotest
Auto Test - Sending a communicator test at a specified interval.
Start Prog
Start Programming - Local programming is started.
End Prog
End Programming - Local programming is ended.
Start Dnld
Start Download - Download session is started.
End Dnld
End Download - Download session is ended.
Cancel
Cancel - System is disarmed; Cancel was initiated within 5 minutes
of an alarm.
Gnd Flt
Ground Fault - A short to ground has been detected.
Man Test
Manual Test - Bell and/or communicator test while system is in
disarmed condition.
Re-exit
Re-Exit - The exit delay has been re-started without disarming the
system.
Output Trip
Output Trip - A trip has occurred on an expander auxiliary output.
Data Lost
Data Lost - Communication of a signal has failed (log only event).
Walk-test
Walk-Test - A zone “Walk-Test” mode has been activated.
End Test
End Test - Test has been ended.
Cross-Trip
Cross Trip - The first zone of a cross zone has been tripped (log only
event).
Expansion Event
Expansion Event - An expansion module has created an undefined
event.
Partial Arm
Partial Arm - Reports a closing in the stay mode.
Event
User or Zone ID
Indicates partition
a
nd
7
indicates an
e
vent not reported
Date
(
Month/Dat
e)
Time