Simon XT User Manual 21
Communication troubles with the central monitoring station
When your security system detects one of the problems above, six rapid beeps
sound every minute until the trouble condition is corrected. To stop the trouble
beeps, press STATUS or arm/disarm the system while the trouble condition
exists. Trouble beeps will resume four hours later unless the trouble condition is
corrected.
The following list explains the trouble beep conditions:
AC power failure
This condition (if programmed by installer) occurs if your security system has
been accidentally unplugged or if there has been an AC power outage. Any
status lights go out immediately, and trouble beeps start after five minutes. If you
press any button, the display will light and pressing STATUS will show the AC
failure. If AC power is not restored within a programmed period of time (5 to 254
minutes) the system will call the central monitoring station. The backup battery, if
fully charged, will last for 18 to 24 hoursdepending on the load applied to the
panelwith no AC power.
In a UL installation, a new, fully charged backup battery will last 24 hours with the
panel in normal standby condition and still sound an alarm.
System battery failure
This condition occurs if the emergency backup battery has failed. Trouble beeps
will start. Press the STATUS button and the display will show System Low
Battery. If your AC power is not working, your security system will shut down
once the battery has failed. If the condition does not clear after AC power has
been restored and 24 hours have passed, call your security system dealer.
Restoration of power
This condition occurs after a complete loss of power (AC and battery). When
power is restored, the panel will return to the arming state with the same zones
bypassed it had prior to losing power.
Sensor failure
This condition occurs if a sensor is not communicating with the panel. Trouble
beeps will start and the STATUS button will light. Press the STATUS button and
the display will show what sensors have failed. Perform sensor tests. You may
need to call your security system dealer if the problem continues.
Sensor low battery
This condition occurs if a system sensor has a low battery. The sensor may still
be communicating with the panel. Trouble beeps will start and the STATUS
button will light. Press the STATUS button and the display will show what

Other manuals for Interlogix Simon XT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix Simon XT and is the answer not in the manual?

Interlogix Simon XT Specifications

Power IconPower
power requirements6V nominal
standby current30mA (10mA in PowerSave Mode)
peak current1.7 A
Operating Environment IconOperating Environment
operating temperature32 to 120°F (0 to 49°C)
storage temperature-30 to 140°F (-34 to 60°C)
max. relative humidity90% non-condensing
Dimensions IconDimensions
height4 1/16 in.
width1 7/8 in.