26 Simon XT User Manual
1. Scroll up/down until the display reads Light Schedules.
2. Press Enter. The current setting will flash.
3. Scroll up/down to toggle scheduled lights On/Off.
4. Press Enter. The setting will stop flashing.
5. Press STATUS to exit.
A clock icon appears in the display when scheduled lights are enabled.
Note: This feature is not verified for use by UL. This menu option will not appear
if no light schedules are defined.
Sensor lights
Simon XT automatically turns certain lights on or off when certain sensors are
tripped. For example, you can set a basement light to turn on when the door to
the basement is opened. You can associate sensors with lights in menu item
System programming / Light control / Sensor light. See Light control (optional)
on page 14.
To enable or disable sensor-activated lights:
1. Scroll up/down until the display shows Sensor Lights.
2. Press Enter. The current setting will flash.
3. Scroll up/down to toggle the sensor-activated lights On/Off.
4. Press Enter. The setting will stop flashing.
5. Press STATUS to exit.
A light-bulb icon will appear in the display when Sensor lights are enabled.
Note: This feature is not verified for use by UL. This menu option will not appear
if no sensor lights have been defined.
Chime
To enable or disable the Chime feature:
1. Scroll up/down until the display shows Chime.
2. Press Enter. The current setting will flash.
3. Scroll up/down to toggle Chime on/off.
4. Press Enter. The setting will stop flashing.
5. Press STATUS to exit.
A solid bell icon will appear in the display when Chime is enabled.
Note: This menu option will not appear if no chime sensors are in your system

Other manuals for Interlogix Simon XT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix Simon XT and is the answer not in the manual?

Interlogix Simon XT Specifications

Power IconPower
power requirements6V nominal
standby current30mA (10mA in PowerSave Mode)
peak current1.7 A
Operating Environment IconOperating Environment
operating temperature32 to 120°F (0 to 49°C)
storage temperature-30 to 140°F (-34 to 60°C)
max. relative humidity90% non-condensing