HUD Visual Pressure Gauge and Visual Warning, BAC and DDU Visual Warning
A wireless Heads-Up Display (HUD) inside the face mask acts as a secondary visual
pressure gauge and also provides visual low air warnings at both 1/2 and 1/3
cylinder pressure. Flashing yellow and red LED’s will activate when the primary air
supply pressure has dropped to approximately 50% and the ashing red LED only at
approximately 33%. The visual ashing red LED will continue to ash until the cylinder
content is depleted and the unit is switched off.
Flashing red LEDs are also activated on the BAC and the Digital Display unit at 1/3
cylinder pressure for other reghters to see.
1.8 INTEGRATED PASS
The PASS is automatically activated by air pressure from the SCBA and put into
Sensing mode. The unit may be put into Alarm from Sensing mode at any time by
pressing the red alarm button on the DDU.
When in Alarm the unit may be reset to the Sensing mode by pressing the black
backlight button two times or by rst pressing and holding the black backlight button
and then simultaneously pressing the red alarm button on the DDU.
The unit may be turned Off by closing the cylinder valve, evacuating air from the
system and then by pressing the black backlight button two times or pressing and
holding the black backlight button and then simultaneously pressing the red alarm
button on the DDU.
The internal data logging records dates and times including:
Power On
Pre-Alert and Lack of Motion Alarm
Manual Alarm
• Reset
Power Off
Low Battery Warnings.
The data log information can be downloaded to a PC using the data log transfer
software “InMode” and a USB dongle. Contact Interspiro for additional information.
The PASS can be used without having the SCBA pressurised and is activated by
pressing the red alarm button on the DDU. This will activate the PASS and start the
Alarm mode, reset the PASS by pressing the black backlight button two times or by
pressing and holding the black backlight button and then simultaneously pressing the
red alarm button on the DDU. The PASS is now in Sensing mode.