EMERGENCY BREATHING SAFETY SYSTEM (EBSS) SPECIAL OR CRITICAL USER’S INSTRUCTIONS:
-ACTIVATION OR ENGAGEMENT OF EBSS IN EITHER THE DONOR OR RECEIVER MODE CHANGES THE SCBA
USE TO ESCAPE-ONLY, APPROVED SERVICE TIME FOR EITHER THE DONOR, OR THE RECEIVER IS NO LONGER
APPLICABLE.
-ENTRY APPROVAL ONLY RESTORED AFTER RE-CHARGE, EITHER HOST OR DONOR.
-EBSS MAY NOT BE ENGAGED OR ACTIVATED IN DONOR MODE AFTER THE DONOR END-OF-SERVICE-TIME-
INDICATOR (EOSTI) HAS ACTIVATED.
- IMMEDIATELY AFTER THE EBSS CONNECTION HAS BEEN COMPLETED, THE CYLINDER VALVE OF THE RECEIVING
SCBA SHALL BE CLOSED.
-USERS MUST BE FULLY TRAINED IN THE OPERATION OF EBSS IN ACCORDANCE WITH A TRAINING PROGRAM
CONFORMING TO THE REQUIREMENTS OF NFPA STANDARDS 1404, FIRE SERVICE RESPIRATORY PROTECTION
TRAINING AND 1500, FIRE DEPARTMENT OCCUPATIONAL SAFETY AND HEALTH PROGRAM.
-SIMULTANEOUS CONNECTION OF MORE THAN TWO USERS, ONE DONOR AND ONE RECEIVER, IS NOT
PERMITTED.
-NOT SUITABLE FOR CONNECTION IN CBRN ENVIRONMENT.
-EBSS FEMALE AND MALE FITTINGS MEET THE DESIGN REQUIREMENTS OF NFPA 1981, 2019 EDITION.
-EBSS (WHEN EQUIPPED) IS STORED IN AN EXTRA AIR POUCH LOCATED ON THE LEFT HIP OF THE SCBA.
-TO MEET THE UNIVERSAL EMERGENCY SAFETY SYSTEM (UEBSS) REQUIREMENTS OF NFPA 1981, 2019 EDITION,
THE POUCH IS LABELED UEBSS IN BLACK 1” (25 MM) LETTERS ON A SILVER REFLECTIVE BACKGROUND.
During an emergency rescue operation, the following procedure shall be followed.
• The person making the rescue shall remove the Y-coupling rescue hose from the
left hip pouch of his/her own SCBA and from the person to be rescued. The
rescuer shall connect the Y-couplings together.
• Push the female connector of one Y-coupling onto the male coupling of the other.
The locking sleeve of the quick coupling will automatically move forward and
snap into place, locking the hoses together.
• Gently pull the hoses to ensure, that the couplings are secure.
• The rescuer shall listen for a strong ow of air from the SCBA of the person to be
rescued.
A: A strong ow of air would indicate a leakage on the SCBA of the person to be
rescued. If a strong leakage is heard, disconnect the rescue hose before the donor
loses his/her own air. Then call for a rescue team and use INTERSPIRO’s Revitox
mask.
B: If a strong ow of air leakage is not heard, close the cylinder valve of the
receiving SCBA. Proceed together and leave the contaminated area.