EasyManua.ls Logo

INTERSPIRO S9 - Page 35

INTERSPIRO S9
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
35
EMERGENCY BREATHING SAFETY SYSTEM (EBSS) SPECIAL OR CRITICAL USER’S INSTRUCTIONS:
-ACTIVATION OR ENGAGEMENT OF EBSS IN EITHER THE DONOR OR RECEIVER MODE CHANGES THE SCBA
USE TO ESCAPE-ONLY, APPROVED SERVICE TIME FOR EITHER THE DONOR, OR THE RECEIVER IS NO LONGER
APPLICABLE.
-ENTRY APPROVAL ONLY RESTORED AFTER RE-CHARGE, EITHER HOST OR DONOR.
-EBSS MAY NOT BE ENGAGED OR ACTIVATED IN DONOR MODE AFTER THE DONOR END-OF-SERVICE-TIME-
INDICATOR (EOSTI) HAS ACTIVATED.
- IMMEDIATELY AFTER THE EBSS CONNECTION HAS BEEN COMPLETED, THE CYLINDER VALVE OF THE RECEIVING
SCBA SHALL BE CLOSED.
-USERS MUST BE FULLY TRAINED IN THE OPERATION OF EBSS IN ACCORDANCE WITH A TRAINING PROGRAM
CONFORMING TO THE REQUIREMENTS OF NFPA STANDARDS 1404, FIRE SERVICE RESPIRATORY PROTECTION
TRAINING AND 1500, FIRE DEPARTMENT OCCUPATIONAL SAFETY AND HEALTH PROGRAM.
-SIMULTANEOUS CONNECTION OF MORE THAN TWO USERS, ONE DONOR AND ONE RECEIVER, IS NOT
PERMITTED.
-NOT SUITABLE FOR CONNECTION IN CBRN ENVIRONMENT.
-EBSS FEMALE AND MALE FITTINGS MEET THE DESIGN REQUIREMENTS OF NFPA 1981, 2019 EDITION.
-EBSS (WHEN EQUIPPED) IS STORED IN AN EXTRA AIR POUCH LOCATED ON THE LEFT HIP OF THE SCBA.
-TO MEET THE UNIVERSAL EMERGENCY SAFETY SYSTEM (UEBSS) REQUIREMENTS OF NFPA 1981, 2019 EDITION,
THE POUCH IS LABELED UEBSS IN BLACK 1” (25 MM) LETTERS ON A SILVER REFLECTIVE BACKGROUND.
During an emergency rescue operation, the following procedure shall be followed.
The person making the rescue shall remove the Y-coupling rescue hose from the
left hip pouch of his/her own SCBA and from the person to be rescued. The
rescuer shall connect the Y-couplings together.
Push the female connector of one Y-coupling onto the male coupling of the other.
The locking sleeve of the quick coupling will automatically move forward and
snap into place, locking the hoses together.
Gently pull the hoses to ensure, that the couplings are secure.
The rescuer shall listen for a strong ow of air from the SCBA of the person to be
rescued.
A: A strong ow of air would indicate a leakage on the SCBA of the person to be
rescued. If a strong leakage is heard, disconnect the rescue hose before the donor
loses his/her own air. Then call for a rescue team and use INTERSPIRO’s Revitox
mask.
B: If a strong ow of air leakage is not heard, close the cylinder valve of the
receiving SCBA. Proceed together and leave the contaminated area.