10.7 STORING THE APPARATUS
Upon completion of all required service, the SPIROMATIC S should be stored in the
carrying case if supplied with the unit, or in the walk away bracket.
When mounting the S9 SCBA in a re apparatus jumpseat, check that there is no
interference between the SCBA and the seat. Check that the SCBA and cylinder are
properly secured and can be removed easily without damaging the components.
Store the apparatus ready for use. The apparatus should be stored in dry conditions,
well protected from direct sunlight and extremes of temperature.
The mask assembly should be stored in a mask bag.
Store the SPIROMATIC S mask and breathing valve with the positive pressure turned
on (see section 1.3 for instructions).
The cylinder must be fully charged and ready for use.
10.8 MARKING RECOMMENDATIONS AND RESTRICTIONS
Special user identication/marking on SCBA equipment must be accomplished in a
manner that does not interfere with regulatory labels i.e. NIOSH, NFPA, DOT. Further,
manufacturer traceability markings such as embossed serial numbers or part numbers
can not be obscured.
Marking of SCBA cylinders and/or other SCBA components may be done with a non-
ammable marking medium.