EasyManua.ls Logo

INTERSPIRO Spiromatic 90U - Additional Features and Service; Extra Air Connection; Markings; Service and Testing Schedule

INTERSPIRO Spiromatic 90U
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH
EXTRA AIR CONNECTION
Some models are equipped with an extra air connection which can be used to:
. Connect to a chemical suit ventilation system
. Connect a rescue hose between two apparatuses
. Connect an extra mask
. Connect the resuscitation mask Revitox
. Feed the apparatus from an external air source
When taking air from the apparatus, point 1-4 above, the air consumption increases
and the duration of the apparatus decreases.
A special female coupling with a non-return valve opener must be used when taking
air from the apparatus, point 1-4 above. This device opens the non-return valve in the
male connection on the apparatus.
ATTENTION! WHEN FEEDING THE APPARATUS FROM AN EXTERNAL AIR SOURCE, THIS KIND OF FEMALE COUPLING MUST
NOT BE USED. IN THIS APPLICATION THE NONRETURN VALVE IN THE MALE CONNECTION MUST BE ABLE TO CLOSE IN
CASE OF DISRUPTION IN AIR SUPPLY FROM THE EXTERNAL SOURCE.
 MARKINGS
A. Manufacturer
B. Model designation
C. Serial No
D. European standard and classication
E. Year of manufacture
 SERVICE AND TESTING SCHEDULE
Service and testing shall be performed according to Service and testing schedule
97307. Visit www.interspiro.com for latest revision.
AFTER EACH USE
. Switch o the positive pressure (if applicable).
. Open the cylinder valve fully and read o the pressure gauge.
. Close the cylinder valve.
. Check that the pressure do not drop.
. Decrease the cylinder pressure slowly and check that the whistle starts sounding
at 55±5 bar.
When taking air from the apparatus, point 1-4 above, the air consumption increases
and the duration of the apparatus decreases.
A special female coupling with a non-return valve opener must be used when taking
air from the apparatus, point 1-4 above. This device opens the non-return valve in the
male connection on the apparatus.
A
B
C
D
E

Table of Contents