297
A
S AVE THESE INSTRUCTIONS
(297IO) SPA (JET + HARD WATER) ENGLISH 7.5” X 10.3” PANTONE 295U 07/26/2016
English
Page 13
LED CODE CHART
E90
No water fl ow
• Turn off and unplug the control unit.
• Ensure the outlet cover grid is clean and free
from obstructions.
• Clean or replace the cartridge, see
Maintenance and Storage section.
• Ensure the in/outlet connections on the spa tub
and fi lter pump are not blocked.
• Keep the spa water properly sanitized to
ensure a clean and unclogged fi lter cartridge.
• Press the button to turn off the unit.
Release trapped air by unscrewing the drain
valve cap on the control base side with a coin.
Air has been release once a steady stream of
water is fl owing out from the drain valve. Wait
for 15 seconds and screw the drain valve cap
back. Press the button to activate the
control panel buttons, and then run the fi lter
function by pressing the button to push
out any remaining air in the system.
• If problem persists, contact Intex Service
Center.
E94
Water temperature too low
• If the ambient temperature is below 4°C (39°F),
we recommend not to use the spa.
• Turn off and unplug the control unit, add some
warm water to raise the spa water temperature
above 5°C (41°F), then press the button to
heat up the water to the desired temperature.
• If problem persists, contact Intex Service
Center.
E95
Water temperature is around
50°C (122°F)
• Turn off and unplug the control unit. When the
water has cooled down, plug the RCD and
restart all over again.
• Turn the heater off, then press the fi lter and jet
buttons to lower the water temperature.
• If problem persists, contact Intex Service
Center.
E96
System Error
• Turn off and unplug the control unit, use the
cap to stop the water from fl owing out of the
tub, disassemble and drain out the control unit.
Reassemble the control unit back to the tub.
Plug the RCD and restart all over again.
• If problem persists, contact Intex Service Center.
E97
Dry-fi re Protection • Contact Intex Service Center.
E99
Water temperature sensor broken • Contact Intex Service Center.
END
After 72 hours of continuous
heating operation, the pump will
hibernate automatically. The rapid
heating and water fi ltration
functions are disabled.
• Press the button to re-active the
fi lter pump.
LED Reading CAUSE SOLUTION