64
12 Technical Specications
Permissible Operating and
Storage Conditions
Temperature range for operation
according to ISO 7176-9:
• -25 … +50 °C
Temperature range for storage
according to ISO 7176-9:
• -40 … +65 °C
Electrical system
Motor
• 6 km/h: S1: 240 W, Max
peak
500 W
• 10 km/h: S1: 240 W, Max
peak
600 W
• 12 km/h: S1: 250 W, Max
peak
1200 W
Batteries
• 2 x 12V / 40 Ah (C20) Gel
• 2 x 12V / 50 Ah (C20) AGM
Main fuse
• 70 A
Charging device
Output current
• 8A ±
Output voltage
• 24V nominal (12 cells)
Input voltage
• 200 – 250V nominal
Operating temperature
(surroundings)
• -25° ... +50°C
Storage temperature
• -40° ... +65°C
Tyres
Tyre type
• 4.10 / 3.50 - 5 pneumatic
Tyre pressure
• 2.8 bar
NB: Not all models listed in the below tables may be available in your region.