Page 7
Page 6
Unit Specications and Features
1
NOTE:
A guide on using the infrared remote is not included
in this literature package.
Unit Parts
fresh defrost run timer
Power Cable (not available)
Remote Control
Remote Control Holder
Louver
Front Panel
Display window(A)
Display window(B)
Display window(C)
“ ” for 3 seconds when:
• TIMER ON is set
• FRESH, SWING, TURBO, or SILENCE features are turned on
“ ” when Fresh feature is activated (some units)
“ ” for 3 seconds when:
• TIMER OFF is set
• FRESH, SWING, TURBO, or SILENCE features are turned off
“ ” when defrosting
“ ” when anti-cold air feature is turned on
“ ” when unit is self-cleaning
“ ” when freeze protection is turned on
“ ” when defrost feature is activated.
Display Code
Meanings
In Fan mode, the unit will display the room temperature.
In other modes, the unit will display your temperature setting.
,
,
“ ” Not available for all units.
When ECO function (some units) is activated, the
illuminates gradually one by one as --
-- --set temperature -- ...... in one second interval.
fresh defrost run timer
“ ” when the unit is on.
“ ” when TIMER is set.
When error occurs, it displays error code.
fresh
defrost
run
timer
“ ” when Wireless Control feature is activated (some units)
and Features
Page 7
Achieving Optimal Performance
Optimal performance for the COOL, HEAT, and DRY modes can be achieved in the following
temperature ranges. When your air conditioner is used outside of these ranges, certain safety
protection features will activate and cause the unit to perform less than optimally.
Room
Temperature
17°-32°C (63°-90°F)
0°-30°C (32°-86°F)
10°-32°C (50°-90°F)
Outdoor
Temperature
18°-43°C (64°-109°F)
-7°-24°C (19°-75°F)
11°-43°C (52°-109°F)
-7°-43°C (19°-109°F)
(For models with low-temp cooling systems)
18°-43°C (64°-109°F)
18°-54°C (64°-129°F)
(For special tropical models)
18°-54°C (64°-129°F)
(For special tropical models)
COOL mode HEAT mode DRY mode
COOL mode
HEAT mode
DRY mode
Room Temperature
17°C - 32°C
(63°F - 90°F)
0°C - 30°C
(32°F - 86°F)
10°C - 32°C
(50°F - 90°F)
Outdoor
Temperature
0°C - 50°C
(32°F - 122°F)
-15°C - 30°C
(5°F - 86°F)
0°C - 50°C
(32°F - 122°F)
0°C - 60°C
(32°F - 140°F)
(For special
tropical models)
0°C - 60°C
(32°F - 140°F)
(For special
tropical models)
-15°C - 50°C
(5°F - 122°F)
(For models with
low temp. cooling
systems.)
To further optimize the performance of your unit, do the following:
Keep doors and windows closed.
Limit energy usage by using TIMER ON and TIMER OFF functions.
Do not block air inlets or outlets.
Regularly inspect and clean air lters.
FOR OUTDOOR UNITS
WITH AUXILIARY
ELECTRIC HEATER
Inverter Split Type
Fixed-speed Type
When outside
temperature is below 0°C
(32°F ), we strongly
recommend keeping the
unit plugged in at all
time to ensure smooth
ongoing performance.

Other manuals for INVENTOR PR1VO32-12B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVENTOR PR1VO32-12B and is the answer not in the manual?

INVENTOR PR1VO32-12B Specifications

General IconGeneral
BrandINVENTOR
ModelPR1VO32-12B
CategoryAir Conditioner
LanguageEnglish

Related product manuals