Version 4 Rev 1 Apr 2011 INVOLAR Corporation Ltd. (EUR)
31
Code designation:
PV1F;
Rated voltage AC U0/U 0,6/1 kV; ambient temperature:–40 °C to +90 °C; Max.
conductor temperature: 120 °C; TUV or equivalent approved recommended.
All positive connections shall be made with Red insulated wire, and all negative
connections with Black insulated wires.
To guarantee the degree of protection IP65, the installation connector and
connector shall be used based on its manual.
Detailed Installation Procedure
Installation in the following sections is numerically referenced in the installation
Figure 5-2 below.
Figure 5-2 MAC250 Micro-Inverter Installation
DANGER
Be aware that only qualified personnel could connect
INVOLAR Micro-Inverter to the electrical utility grid.
DANGER
DO NOT connect INVOLAR Micro-Inverter to the utility grid
or energize the AC circuit(s) until the all installation
procedures have been completed.
WARNING
Effective grounding during Micro-Inverters are working.
Comply the rules of correctly use of tools and personal
protective equipment (PPE) for insuring the Micro-Inverter
safe running.