BPD series PV pumping inverter Product overview
8
2.4 Power levels
BPDXKXTN
0K7
1K5
2K2
004
Rated output power (kW)
0.75
1.5
2.2
4
Max. DC input current (A)
9
12
12
20
Rated AC input current––AC model (A)
9.3
15.7
24
38
Rated output current (A)
5.1 (1PH)
4.2 (3PH)
10.2 (1PH)
7.5 (3PH)
14 (1PH)
10 (3PH)
25 (1PH)
16 (3PH)
BPDXKXTRAC(S)
2K2
004
5K5
Rated output power (kW)
2.2
4
5.5
Max. DC input current (A)
12
20
20
Rated AC input current––AC model (A)
5.8
13.5
19.5
Rated output current (A)
5.5
9.5
14
2.5 Control circuit wiring and terminals
2.5.1 Wiring diagram of the control circuit
The COM interfaces are the control circuit interfaces, including one 485 communication
channel and three digital input channels. Figure 2.1 shows the wiring. For interface
definitions and specifications, see section 2.5.4 "Description of function terminals".