Rack-online UPS
(1-3kVA)
User Manual

Questions and Answers:

INVT HT1101S Specifications

General IconGeneral
BrandINVT
ModelHT1101S
CategoryUPS
LanguageEnglish

Summary

Important Safety Instructions

General Safety Precautions

Adhere to all warnings, maximum load limits, and operating instructions for safe UPS use.

Battery Safety Precautions

Follow specific precautions when handling batteries due to electrical shock and short circuit risks.

Electromagnetic Compatibility

Safety and EMI/EMS Standards

Details safety compliance and electromagnetic interference/sensitivity standards for the UPS.

Operating Environment and Notices

Specifies operating conditions, prohibited actions, and cleaning instructions for safe UPS operation.

Introduction

UPS Overview and Capabilities

Introduces the 1-3kVA UPS, its purpose, and features like LCD display and function buttons.

System Description

Transient Voltage Surge Suppression and EMI/FRI Filters

Explains surge protection and filtering of electromagnetic and radio frequency interference.

Rectifier/Power Factor Correction (PFC) Circuit

Describes how the PFC circuit converts AC to DC and improves input current waveform.

Inverter Function

Explains the inverter's role in converting DC to AC for clean, regulated output power.

Battery Charger and DC-to-DC Converter

Details the battery charger's function and the DC-to-DC converter's role in voltage regulation.

Battery and Dynamic Bypass

Covers battery types, operating temperature, and the automatic transfer to bypass during UPS malfunction.

Product Specification and Performance

Model Description

Identifies applicable models, distinguishing between standard and long backup time variants.

General Specification

Lists power rating, frequency, input/output voltage, battery numbers, dimensions, and weight for 1K, 2K, 3K models.

Electrical Performance

Details input electrical characteristics like voltage, frequency, and power factor.

Output Specifications

Outlines output voltage regulation, power factor, frequency tolerance, distortion, and overload capacity.

Operating Environment

Defines temperature, humidity, altitude limits, and storage temperature for optimal UPS operation.

Installation

Unpacking and Inspection

Instructions for unpacking the UPS, checking contents, and inspecting for transport damage.

Mechanical Installation

Covers installation modes, notes, and procedures for tower installation.

External Battery Connection

Procedure for connecting external battery packs for long backup time models, including voltage and current considerations.

Controls and Indicators

Operation and Display Panel

Identifies and explains the functions of the ON/OFF and FUNC buttons on the display panel.

Indicator Lights

Explains the meaning of REC, INV, BYP, and BAT indicator lights based on their color and status.

LCD Main Menu Display

Details the information displayed on the LCD screen, including input, warn, battery, load, and output status.

Audible Alarms

Lists conditions like battery discharge, low battery, and overload that trigger audible alarms.

Operation

UPS Power On/Off Procedures

Provides step-by-step instructions for turning the UPS on in normal mode or from battery, and turning it off.

Battery Maintenance

Routine Maintenance

Guidelines for charging, lifespan, and replacement of UPS batteries, emphasizing qualified personnel.

Replacing Internal Battery Pack

Detailed steps for safely removing and replacing the internal battery pack of the UPS.

Battery Disposal and Replacement Procedures

Disposal Precautions

Safety guidelines for disposing of batteries, including personal protection and avoiding fire hazards.

Replacement Steps

Procedure for replacing batteries, including disconnecting wires, removing fasteners, and reconnecting.

Troubleshooting

Status Checks and Fault Codes

Recommendations for checking UPS status and identifying fault/warn codes.

Fault and Warn Code Resolution

Lists common fault/warn codes, their possible causes, and solutions for troubleshooting UPS issues.

Specific Fault/Warning Scenarios

Details specific fault and warning conditions like inverter fault, over-temperature, and fan failure with contact information.

Reporting UPS Faults

Information required when reporting a UPS fault, including model, serial number, and fault codes.

Intelligent Slot

Slot Functions and Wiring Diagrams

Details the pin functions and wiring diagrams for DB9 and Phoenix terminator intelligent slots.

EPO (Emergency Power Off)

EPO Functionality

Explains the optional EPO function for complete UPS shutdown in emergencies via remote contact.

Rated Parameters Setting

Entering Setting Mode and Voltage/Frequency Configuration

Procedure to enter setting mode and set UPS voltage and frequency using panel buttons.

Mode and Protocol Configuration

Instructions for configuring operating mode (normal/ECO) and communication protocol (Modbus/SNT).

Saving and Exiting Settings

Process for saving the current settings or exiting the setting mode without saving.

Battery Kit Assembly

1k Battery Kit Assembly

Step-by-step instructions for assembling the 1k battery kit, including tape removal and connection.

2k Battery Kit Assembly

Instructions for assembling the 2k battery kit, covering tape removal, terminal connection, and shell assembly.

3k Battery Kit Assembly

Guide for assembling the 3k battery kit, detailing tape removal, battery connection, and final assembly.