Single Phase Hybrid Inverter Installation
13
4.5 Product Dimension and Weight
Fig. 4.8 Overall Dimension of Inverter
Dimension and net weight of hybrid inverter:
Dimension and gross weight
Model
Height
(mm)
Width
(mm)
Depth
(mm)
Weight
(kg)
Package
material
XD3~6KTL
485
575
320
26
Corrugated
case
4.6 Wall Mounting
Step 1: The thickness of the wall for wall-mounted installation should be greater than or equal to 60mm. Using
a marker and a spirit level, mark the points where you need to drill the holes.
Step 2: Drill the holes (diameter: φ8; depth: ≥55mm) using a hammer drill, and then install M6×50 stainless-
steel expansion bolts.
D
H
W
Model No.
Height (H)
(mm)
Width (W)
(mm)
Depth (D)
(mm)
Net Weight
(kg)
XD3~6KTL
390
481
200
22