15
Open
7 8 96
10
Closed
Entry
CF Prefiltra-
tion
RO Mem-
brane
CB Postfiltra-
ción
Measuring
cup
Q u a l i t y
sensor
Closed
Opened
Opened
- Once the unit is installed, keep the new manual inlet
valve closed and open the inlet valve connected to the
wall adapter (7). The measuring cup must be empty.
- Pour 0.25 litres of hydrogen peroxide into the measu-
ring cup inserted in the equipment inlet (8). Thread the
beaker correctly to its head.
- The manual inlet valve and the tap must be closed.
Connect the equipment to the power supply.
- Open the water inlet tap to the equipment and to the
faucet, allowing its operation to start and allowing the
Hydrogen Peroxide to be sucked into it. Fill a 1L carafe
with tap water. Before closing the faucet, close the inlet
tap again to lower the pressure. Fill the dispenser again
with 0.25l of hydrogen peroxide and empty 1 litre more
of water. Turn off the tap. At this moment the whole
circuit contains sanitizing liquid.
- After 10 mins. open the dispenser tap (9) and let the
mains water circulate for 5 mins.
- Empty the measuring cup. Before opening it, have a
container within reach where you can empty it, as it
may be filled with water.