Maintenance
Terminals should be periodically checked for oxidation or loose connections and cleaned or tightened as
necessary. No other maintenance is required. Poor electrical connections can cause performance problems
with uSTART
®
. Prior to removal or system maintenance, ensure that uSTART
®
is in Maintenance Mode.
uSTART
®
can be cleaned while in Maintenance Mode by use of a cloth and simple soap and water solution.
Avoid the use of hoses or pressurized sprays.
Troubleshooting
Condition
Item
To
Check
PossibleCause Remedy
RedLED
On
1
OverTemperatureProtection RemoveuSTARTfromthehightemperaturecondition.Allow
uSTARTtocool.ThefaultwillclearassoonasuSTART
returnstoaninternaltemperaturebelow60°C(149°F).If
thisconditionisnotedasoccurringmorethanonceona
particularvehicleareflective
heatshieldmaybeworth
installingbetweenaheatsourceandtheuSTART.
Anenvironmentalconditionabove65°C
(149°F)willcauseuSTARTtoenterFaultMode
inordertoprotecttheproduct.Prolonged
operationabove65°C(149°F)willcause
reducedlifetimeandvoidthewarranty
2
OverPowerorOverCurrentProtection Thefaultconditionwillclearwithin30secondsanduSTART
willreturntoRunMode.Checkforlooseelectrical
connectionsandbatterycondition.
InfrequentactivationofOverPowerProtectiondoesnot
poseanyconcernforuSTARTandcanbeexpectedincertain
applications(ex.
Dieselenginecoldstartswithpreheater,or
extendedheavyliftswithliftgate).
InfrequentactivationofOverCurrentProtectiondoesnot
poseanyconcernforuSTARTandcanbeexpectedunder
conditionsofveryhighload,orifuSTARTterminals
experienceashortcircuit(ex.wrenchcontactsboth
terminals
duringinstallation).
Iffaultmodecontinuestooccurafterthestepsabove,
contactIoxusCustomerService.
Highcurrentorhighcurrentdrawsfor
extendedperiods(beyondnormalengine
crankingtimes)willcauseuSTARTtoenter
faultmodeinordertoensurelongterm
productlifetimeisnotreduced.