For users
- 8 -
3. Technical specification
Model IPS-600 IPS-1200
Advised pool volume (m
3
) 130~260
260~520
Operating air temperature (℃)
-7~43
Performance Condition: Air 26°C, Water 26°C,
Humidity 80%
Hea
60.0
110.0
COP at 50% capacity 10.1 10.0
Performance Condition: Air 15°C, Water 26°C,
Humidity 70%
40.0 81.0
COP at 50% capacity 6.8 6.8
Performance Condition: Air 35°C, Water 28°C, Humidity 80%
Cooling capacity (kW) 26.5 54.0
Sound pressure at 1m dB(A) 54.0~62.0 56.0~65.0
Sound pressure of 50% capacity at 1m
dB(A)
56.0 58.0
Sound pressure at 10m dB(A) 34.0~42.0 36.0~45.0
Compressor DC inverter
Heat exchanger Spiral titanium tube in PVC
Casing Aluminum-alloy
Fan direction Vertical
Power supply 400V/3Ph/50Hz
Rated input power at air 15°C (kW) 2.20~8.03
4.69~17.6
Rated input current at air 15°C (A) 3.17~11.59
6.77~25.4
Advised water flux (m³/h) 20~25
40~50
Water pipe in-out size (mm) 75
110
Net dimension LxWxH (mm) 1110x1023x1260
2100×1090×1280
Net weight (kg) 230
448
The values indicated are valid under ideal conditions: Pool covered with an isothermal cover,
filtration system running at least 15 hours a day.
Related parameters are subject to adjustment periodically for technical improvement without
further notice. For details please refer to nameplate.