STATUS POSSIBLE CAUSE REMEDY
Not running
No air coming out
Power plug is not securely plugged into
the electric socket.
Please plug the power plug securely into
the electric socket.
START/ON button has not been pressed. Please press the START/ON button.
Air temperature does not change
This is normal as the product is adjusting the temperature.
Blanket is not dry
Blanket is not warmed up
Trying to dry several blankets at once. Please dry one blanket at a time.
Air filter is dirty. Please clean the air filter (P12).
The blanket is not laid out correctly.
Please lay down the blanket correctly
(P7).
The blanket is too heavy.
Please lift the blanket a little so warm
air can reach the bottom of the heavy
blanket.
The air flap is not opened. Please open the air flap (P7).
The air entry port or air outlet is blocked.
Please remove anything blocking the
air entry port or air outlet and run the
product again.
The air entry port or suction port is too
close to the wall.
Please keep the product at least 15cm
away from the wall.
Error code is indicated as [E1]
Air entry port on right side is facing
down when choosing the mode.
Please place the product in the correct
position to dismiss the error.
Error code is indicated as [E2]
Air entry on right side is facing down
while product is running.
Please place the product in the correct
position to dismiss the error the product
again.
Error code is indicated as [E3]
The product is running in an area with
high temperatures or too much warm air
from other heaters.
The product is running with a folded
hose.
The main body temperature is rising
abnormally.
Unplug the power plug from the electric
socket and leave it alone to cool
down. The error will clear off when the
temperature of each part returns to
normal. The product cannot operate
until it temperatures return to normal.
When the error message is dismissed,
the product will automatically restart.
Error code is indicated as [E4]
Error code is indicated as [E6]
Error code is indicated as [E7]
Error code is indicated as [E5]
Product failure has occurred.
Please unplug the power plug from
the electric socket and contact IRIS
Customer Service Center. Do not touch
the product until the main body has
cooled down.
MODEL SPECIFICATIONS
RATED VOLTAGE
120V~
RATED CURRENT
5.2A
RATED FREQUENCY
60 Hz
PRODUCT WEIGHT
3.97lbs. / 1.8kg
PRODUCT SIZE
(NOT INCLUDING THE POWER CORD)
6.3 W x 5.4 D x 14.2 H in
160 W x 137 D x 360 H mm
CORD LENGTH
78.7 in / 2.0m
ATTACHMENTS
Shoe drying attachment
SAFETY DEVICES
Temp Sensor, Thermostat, Thermal Fuse
TIMER
15, 30, 45, 60, 75, 90, 120, 180 minutes
ITEMS INCLUDE
Blanket warmer, shoe drying attachment
*Specifications are subject to change without prior notice.
SPECIFICATIONSTROUBLESHOOTING
Before making repairs, please read the following content carefully to fix common problems.
Problems that could not be resolved.
Please contact the dealer of purchase or IRIS USA, Inc. Customer Service.
Warning:
Do not disassemble, repair or modify the product yourself. Any other servicing should be performed by any
authorized service representative.
13 14

Other manuals for IRIS BLW-C2