What does it mean when my Iron Edison REVOLT4 Inverter SOC LED bar is flashing?
- Ssean74Sep 8, 2025
If the SOC LED bar on your Iron Edison Inverter is flashing, restart the battery by pressing the power button.
What does it mean when my Iron Edison REVOLT4 Inverter SOC LED bar is flashing?
If the SOC LED bar on your Iron Edison Inverter is flashing, restart the battery by pressing the power button.
What to do if my Iron Edison Inverter battery has a short circuit?
If the Iron Edison Inverter battery experiences a short circuit, check the external power wire of the battery, eliminate the short circuit connection, and then restart the battery.
What to do if my Iron Edison REVOLT4 Inverter battery charge/discharge shows over current?
If your Iron Edison Inverter battery is showing an overcurrent during charge or discharge, reduce the charging or discharging current. The battery will automatically release in 1 minute.
What to do if my Iron Edison Inverter shows external COM error with RUN LED?
If your Iron Edison Inverter displays an external COM error with the RUN LED, check the communication cable between the battery and the inverter. Also, verify the inverter selection in the app as per section 7.0, or use V Logic as per section 5.2.3.
What does it mean if the ALM LED is flashing (2hz) on my Iron Edison Inverter?
If the ALM LED on your Iron Edison Inverter is flashing at 2Hz, it indicates a battery address duplication. To resolve this, check the dip switch settings as described in section 5.2.2.
What to do if my Iron Edison REVOLT4 battery shows low voltage?
If your Iron Edison Inverter battery indicates low voltage, stop discharging it and charge the battery within 15 days.
What does solid RUN LED Behavior mean for my Iron Edison Inverter?
Solid RUN LED behavior on your Iron Edison Inverter indicates that no action is required.
What to do if my Iron Edison REVOLT4 Inverter battery shows low temperature?
If your Iron Edison Inverter battery is too cold, stop charging or discharging it until the battery temperature rises above the recovery temperature.
What to do if my Iron Edison REVOLT4 battery shows high temperature?
If your Iron Edison Inverter battery is overheating, stop charging or discharging it until the battery temperature falls below the recovery temperature.
What does it mean if my Iron Edison REVOLT4 shows internal Com Error with ALM LED?
If your Iron Edison Inverter displays an internal Com Error with the ALM LED, check the communication cables and resistors as described in section 5.2.1, or operate V Logic as per section 5.2.3. Refer to section 7.0 for inverter protocols.