10 of 30
When a cycle is properly finished, the needle probe has
reached the right temperature or the time period is
finished, the buzzer sounds and the conservation phase
begins.
The conservation phase is not timed and is only
terminated when the key is pressed.
WARNING The graph available only during the run time.
Power fail reset the screen.
3.2 Hard chilling, soft freezing phase and Holding
The standard cycles are selectable by configuration:
1. CHILLING
2. CHILLING + HOLDING
3. HARD+CHILLING+HOLDING
4. FREEZING
5. FREEZING + HOLDING
6. HARD+FREEZING +HOLDING
CHILLING CYCLES
Enabling the HARD phase the additional low temperature
cabinet and core setpoints are included, see difference
between A and B graphs.
FREEZING CYCLES
Enabling the SOFT phase the additional medium
temperature cabinet and core setpoints are included, see
C graphs.
Infinite HOLDING phase starts at the end of the
CHILLING or FREEZING cycles.
A) CHILLING
B) HARD + CHILLING
C) SOFT+ FREEZING