3.3.2 Multi-timer mode
The time controlled cycle makes it possible to set up to four timers.
The cycle starts up activating only the first timer with its pre-set
values. The other timers and their pre-set values can be enabled by
pressing the pencil icon and setting a time once the cycle is
underway.
When the time period is set and the timer setting confirmed, the timer
count starts up immediately. Each timer operates independently and
on completion of the period it can be reset, starting the timer count
up again.
The cycle only terminates when all the set timers have elapsed. When
the timer count is complete the buzzer sounds and the display shows
in green the value “0 min” for the relevant timer.
3.4 Custom cycle
The customized mode makes it possible to set up a cycle consisting of
a maximum of 4 phases (3 blast chilling and 1
conservation) and these can be temperature or time
controlled or a mixture of both.