5.1 Pre-set blast chilling recipes
Phase 1
Cabinet setting -25°C
Needle probe setting 20°C
Ventilation setting 5
Phase 2
Cabinet setting -5°C
Needle probe setting 3°C
Ventilation setting 5
Conservation
Cabinet setting 5°C
Needle probe setting 2°C
Ventilation setting 5
Phase 1
Cabinet setting -25°C
Duration setting 27 min
Ventilation setting 5
Phase 2
Cabinet setting -5°C
Duration setting 63 min
Ventilation setting 5
Conservation
Cabinet setting 2°C
Ventilation setting 5
Phase 1
Cabinet setting -25°C
Duration setting 27 min
Ventilation setting 5
Phase 2
Cabinet setting -5°C
Duration setting 63 min
Ventilation setting 5
Conservation
Cabinet setting 2°C
Ventilation setting 5
Phase 1
Cabinet setting -5°C
Duration setting 90 min
Ventilation setting 2
Conservation
Cabinet setting 2°C
Ventilation setting 2
Phase 1
Cabinet setting -5°C
Duration setting 90 min
Ventilation setting 5
Conservation
Cabinet setting 2°C
Ventilation setting 5
Phase 1
Cabinet setting -5°C
Duration setting 90 min
Ventilation setting 5
Conservation
Cabinet setting 2°C
Ventilation setting 5
5.2 Pre-set blast-freezing recipes
Phase 1
Cabinet setting 0°C
Needle probe setting 3°C
Ventilation setting 5
Phase 2
Cabinet setting -12°C
Needle probe setting -3°C
Ventilation setting 5
Phase 3
Cabinet setting -30°C
Needle probe setting -18°C
Ventilation setting 5
Conservation
Cabinet setting 5°C
Needle probe setting -20°C
Ventilation setting 5