Crest Factor :
1.4 to 2: +0.5%
Crest Factor
= Peak value
2 to 2.5: +2% True r.m.s. value.
2.5 to 3: +4%
D.C. current (Ad.c.)
Range Resolution Accuracy (97) Voltage drop
300µA 0.1 µV ±(1% + 2D)
3mA 1µA
30mA 10µA
300mA 0.1mA
10A 10mA
200mV (max.)
Accuracy (97RMS)
±(1% + 2D)
±(1.2% + 2D)
±(1% + 2D)
±(1.2% + 2D)
±(2% + 2D)
±(1.2% + 2D)
±(1% + 2D)
±(1.2% + 2D)
±(2% + 2D)
2V (max.)
200mV (max.)
2V (max.)
2V (max.)
Important :
On the 10A ran
g
e, do not appl
y
currents for measurement of more than 10A for more than 30 seconds.
Old tti
O
ver
l
oa
d
pro
t
ec
ti
on :
A
µ
A
/
/
Ai tt i l1A
m
A
i
npu
t
t
erm
i
na
l
1A
/
/
600V i k
600V
qu
i
c
k
-
ti f
ac
ti
n
g
f
use.
Overload protection :
10A input terminal 15A/600V.