EasyManua.ls Logo

ITech IT6322A

ITech IT6322A
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Output Commands
Copyright© Itech Electronic Co., Ltd. 35
Unit
None
*RST Value
OFF
Example
VOLT:PROT:STAT 1, VOLT:PROT:STAT ON
Query syntax
[SOURce:] VOLTage:PROTection:STATe?
Arguments
None
Example
VOLT:PROT:STAT?
Returns
<0|1>
[SOURce:]VOLTage:PROTection[:LEVel]
This command is used to set the protection voltage upper limit of the power
supply.
Command syntax
[SOURce:] VOLTage:PROTection[:LEVel] <NRf>
Arguments
MIN TO MAX|MIN|MAX
Unit
V | mV
*RST Value
MAX
Example
VOLT:PROT 30V VOLT:PROT MAX
Query syntax
[SOURce:] VOLTage:PROTection[:LEVel]?
Arguments
[MIN|MAX]

Table of Contents

Other manuals for ITech IT6322A

Related product manuals