Type | Programmable DC Power Supply |
---|---|
Storage Temperature | -20°C to 70°C |
Output Voltage | Up to 600V |
Output Voltage Range | 0 to Vmax (depending on model) |
Output Current Range | 0 to Imax (depending on model) |
Voltage Resolution | 1mV |
Current Resolution | 1mA |
Current Accuracy | 0.1% + 5mA |
Load Regulation (CC) | ≤0.02% + 5mA |
Line Regulation (CV) | ≤0.01% + 5mV |
Line Regulation (CC) | ≤0.02% + 5mA |
Interface | RS232 |
Protections | OVP, OCP, OTP |
Display | LCD |
Cooling | Forced air cooling |
Operating Temperature | 0°C to 40°C |
Humidity | < 80%RH |
Weight | Varies by model |
Disclaims warranties and limits liability for the manual.
Content furnished under a license, use according to terms.
U.S. government restrictions on software and technical data.
Denotes a hazard, calls attention to procedures to avoid damage.
Denotes a hazard, calls attention to procedures to avoid injury or death.
Provides important hints and supplementary information for users.
Product warranty terms, duration, and service requirements.
Conditions under which the warranty becomes invalid.
Lists critical safety precautions to observe during operation.
Lists precautions to avoid incorrect use that may void protective features.
Indicates compliance with European legal directives and approval year.
Indicates compliance with Waste Electrical and Electronic Equipment Directive.
Lists European directives and product standards for Electromagnetic Compatibility.
Lists the safety standard the product conforms to.
Steps to check package contents upon delivery for completeness and defects.
Guidance on selecting appropriate installation space based on instrument size.
Overview of IT6500 series, features, and applications.
Description of the front panel layout and key functions of the power supply.
Critical warnings for power-on self-test to prevent damage.
Procedures for normal power-on self-test and expected VFD display.
Steps to verify basic voltage functions without load.
Steps to verify basic current functions with a short across output terminals.
How to switch between local and remote operating modes.
Methods for setting the constant voltage output value.
Steps for connecting multiple power supplies in parallel or series.
Operation for local sense to compensate voltage drop.
Lists modes for analog interface control and monitoring.
Configuration and connection details for RS232 communication.
Table of key electrical and performance specifications for IT6500 series.