Function and Features
Copyright© Itech Electronics Co., Ltd. 41
T11
-
Test 5
Load dump waveform
Test A
select centralized load dump
Unsuppression
Test B
select centralized load dump
suppression
Off
Turn on/off load dump
waveform
On
12V
Select 12V or 24V voltage
system
24V
Td
Pulse width
Un
Peak voltage
Us
clamping voltage
LV124
LV124 waveform protocol
E-02
Transient overvoltage test waveform
Off
Turn on / off this funciton
On
E-04
LV124 E-04
Jump start test waveform
Off
Turn on/off this funciton
On
E-05
LV124 E-05
Load dump test waveform
Off
Turn on/off this function
On
E-07
LV124 E-07
Slow decrease and increase
of the supply voltage test
waveform
Ubmax
Start voltage
Ubmin
Holding voltage
Ubmin
Holding Time
Holding time at Ubmin
Off
Turn on/off this function
On
E-08
LV124 E-08
Slow decrease, quick
increase of the supply voltage
test waveform
Ubmax
Start voltage
Ubmin
Holding voltage
Ubmin
Holding Time
Holding time at Ubmin
Off
Turn on/off this function
On
E-09
LV124 E-09
Reset behavior test waveform
Ubmin
Holding voltage
Off
Turn on/off this function
On
E-11
LV124 E-11
Start pulses
Cold-Start
Cold start
Normal: normal pulse
Severe: severe pulse
Warm-Start
Warm start
Off