R50 Blue Bar 5101171 Rev. L
R50 Blue Bar and
Power Supplies
(D, N & TRUEAC)
INSTALLATION AND OPERATING INSTRUCTIONS

Questions and Answers

  • S
    Steven BarajasAug 10, 2025
    What to do if the fault indicator is ON and there is no output power from the ITW SIMCO ION D Power Supply?
    • D
      Derrick BaileyAug 11, 2025
      If the fault indicator is ON and there's no output power, it might be due to an HV output short to ground. Disconnect the bar and reboot the supply by turning the main power switch off, then back on. If the power supply reboots, replace the bar. If it doesn't reboot, replace the power supply.
  • R
    Rachel WilliamsAug 17, 2025
    What to do if the service indicator is on for ITW Power Supply?
    • J
      john06Aug 17, 2025
      If the service indicator is on, it could be due to several reasons: * HV output short to bar sensor return: Disconnect the bar and reboot the supply. If the supply reboots, replace the bar. * Short bar sensor return to ground: Ensure all bar connections comply with Figure 13, and there are no ground connections to the Shield terminal. * HV transformer fails: If all connections are correct, replace the bar. * Insulative coating on bar: Thoroughly clean the bar to remove any coatings that may be covering points, sides, or the back of the bar. If the condition continues, replace the bar.
  • E
    Ethan FinleyAug 22, 2025
    How to fix no high voltage output on ITW SIMCO ION D?
    • K
      Kristina WoodAug 22, 2025
      If there is no high voltage output, here are a few things to check: * Presence of supply voltage: Replace the transformer or bar. * Absence of supply voltage: Check the supply voltage and connections. * Position of Local/Remote Switch: Make sure the Local/Remote switch is set in the appropriate mode for ON/ OFF control. * No supply voltage: Check supply voltage and connection. * If none of the above: Disconnect the bar and reboot the power supply by turning the main power switch OFF and then back ON. If the supply reboots, replace the bar. If the power supply does not reboot, replace the power supply. * Correct supply voltage: No solution mentioned.
  • M
    Melissa GriffithAug 28, 2025
    What to do if the clean bar indicator will not extinguish after cleaning the ITW SIMCO ION D Power Supply?
    • J
      John MatthewsAug 29, 2025
      If the clean bar indicator won't extinguish after cleaning, consider the following: * The bar is not sufficiently clean: Re-clean the bar. * Sensitivity setting of Clean Bar calibration: If it's a new system, reset the calibration. * Something is touching the bar: Check the bar mounting to ensure no ground path is contacting the bar.
  • A
    Ashley HoganSep 4, 2025
    Why clean bar indicator will not extinguish during calibration of ITW SIMCO ION D?
    • K
      kmillerSep 4, 2025
      If the clean bar indicator won't extinguish during calibration, it might be because the bar is mounted too close to the web or ground. Follow the bar mounting instructions for the R50 Blue Bar.