R50 Blue Bar 5101171 Rev. L
R50 Blue Bar and
Power Supplies
(D, N & TRUEAC)
INSTALLATION AND OPERATING INSTRUCTIONS

Questions and Answers

  • S
    Stephanie MaciasAug 9, 2025
    What to do if the fault indicator is ON and there is no output power from the ITW SIMCO ION 4010442?
    • J
      Janice Gonzalez PhDAug 9, 2025
      If the fault indicator is ON and there's no output power, it might be due to an HV output short to ground. Disconnect the bar and reboot the supply by turning the main power switch off, then back on. If the power supply reboots, replace the bar. If it doesn't reboot, replace the power supply.
  • H
    Heather GriffinAug 15, 2025
    What to do if the service indicator is on for ITW Power Supply?
    • S
      Sharon HarrisonAug 16, 2025
      If the service indicator is on, it could be due to several reasons: * HV output short to bar sensor return: Disconnect the bar and reboot the supply. If the supply reboots, replace the bar. * Short bar sensor return to ground: Ensure all bar connections comply with Figure 13, and there are no ground connections to the Shield terminal. * HV transformer fails: If all connections are correct, replace the bar. * Insulative coating on bar: Thoroughly clean the bar to remove any coatings that may be covering points, sides, or the back of the bar. If the condition continues, replace the bar.
  • E
    Elizabeth CarpenterAug 21, 2025
    How to fix no high voltage output on ITW SIMCO ION 4010442 Power Supply?
    • L
      leesarahAug 21, 2025
      If there is no high voltage output, here are a few things to check: * Presence of supply voltage: Replace the transformer or bar. * Absence of supply voltage: Check the supply voltage and connections. * Position of Local/Remote Switch: Make sure the Local/Remote switch is set in the appropriate mode for ON/ OFF control. * No supply voltage: Check supply voltage and connection. * If none of the above: Disconnect the bar and reboot the power supply by turning the main power switch OFF and then back ON. If the supply reboots, replace the bar. If the power supply does not reboot, replace the power supply. * Correct supply voltage: No solution mentioned.
  • C
    claudia12Aug 27, 2025
    What to do if the clean bar indicator will not extinguish after cleaning the ITW Power Supply?
    • J
      James RiggsAug 27, 2025
      If the clean bar indicator won't extinguish after cleaning, consider the following: * The bar is not sufficiently clean: Re-clean the bar. * Sensitivity setting of Clean Bar calibration: If it's a new system, reset the calibration. * Something is touching the bar: Check the bar mounting to ensure no ground path is contacting the bar.
  • L
    laurabondSep 2, 2025
    Why clean bar indicator will not extinguish during calibration of ITW SIMCO ION 4010442 Power Supply?
    • A
      Alexis CannonSep 2, 2025
      If the clean bar indicator won't extinguish during calibration, it might be because the bar is mounted too close to the web or ground. Follow the bar mounting instructions for the R50 Blue Bar.

Summary

Safety Warnings and Hazards

Electrical Shock Hazard Details

Details electrical shock hazards and necessary precautions during operation and maintenance.

Fire Hazard Precautions

Outlines fire hazards associated with the equipment and essential safety measures.

Technical Specifications

Installation Guidelines

R50 Blue Bar Mounting

Guidance on mounting the R50 Blue Bar, including safety precautions and distance from ground references.

N Power Supply Installation

Instructions for mounting and grounding 'N' type power supplies for safe and efficient operation.

D and TrueAC Power Supply Installation

Installation guidelines specific to 'D' and TrueAC power supplies, including mounting and cable connections.

Operation and Calibration

Troubleshooting Guide

Troubleshooting D Power Supply

Common issues and solutions for 'D' type power supplies, including no high voltage output.

Operating Condition Solutions

Troubleshooting steps for operating conditions like no high voltage output, based on switch position or supply voltage.

Indicator Light Troubleshooting

Diagnosing and resolving issues related to indicator lights such as 'Clean Bar' or 'Fault'.

Service Indicator Light Issues

Specific troubleshooting steps when the 'Service' indicator light is illuminated.

Maintenance Recommendations