EasyManua.ls Logo

ITW SIMCO ION ThunderION 2.0 - 4 Technical Specifications

ITW SIMCO ION ThunderION 2.0
75 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ThunderION2.0_UM_9752160050_NL_D_GB_F_V1_0 43
GB
4 Technical specifications
Required power supply*
Supply voltage 21–27 V DC
Current consumption Max. 2 A DC
Standard cable 1/10m
Connection M12 connector, 5-pin
Output
Output voltage Max. 30 kV positive and negative
Current per emitter to
earth
<150 uA
Environment
Operating environment Industrial
Ambient temperature 0 – 55°C
Cooling Convection
Operating distance 300 – 1000 mm
Local functions
Indication of pulse
frequency setting
Flashing red and green LEDs during start-up of the bar
[On] signaling Green LED
[Error] signaling Red LED lights up in the case of an internal overload or
short circuit.
Red LED flashes when the HV OK output is overloaded
or other errors have been detected (e.g. supply voltage
too low, overheated power supply)
[Warning] signaling
(only IQ version)
Orange LED when Bar needs to be cleaned
Remote functions
(standard version)
Remote On/Off input Switching high voltage on and off
Control voltage specifications:
10 V DC, 10 mA min.
30 V DC, 25 mA max.
Bar operating OK output
(HV OK)
Remote functions
(IQ version)
Indicates that the bar is operating correctly
(when high voltage is switched on).
Uo= Supply voltage — 1 V, Max. 50 mA
Through the IQ Easy manager the bar can be
monitored and controlled (see manual IQ Easy
manager)
Mechanical
Effective bar length 250 mm to 4750 mm
Dimensions (WxHxL) 61 mm x 114 mm x total length (Eff. Length + 195 mm)
Weight 0.8 kg + 2.4 kg/m
Housing
Emitter
Emitterholder
Plastic
Special alloy
Silicone
Mounting material Brackets

Table of Contents

Related product manuals