DIGISPENSE 3009 CONTROLLER MODULE, STYLE B Page 3-51
29 October, 2019 IVEK Corp. P03R017E
3.4.7.7 Setup B Screen
Keylock/Supervisor
D = Display P = Push-button Accessible I/O Test
C = Display/Change N = Not Accessible/Viewable Operator
0 SETUP B < status >
2 AUX OUT 1 = <DISABLED>
3 AUX OUT 2 = <DISABLED>
4 OUTPUT 1 = <READY> PRODUCTION
5 OUTPUT 2 = <STATUS> FAULT
6 OUTPUT 3 = <BUSY> DISCHARGE
7 OUTPUT 4 = <STATUS> REFERENCE
8 INPUT CC 1 = <DISABLED>
9 INPUT CC 2 = <DISABLED>
10 INPUT 1 = <TRIGGER> PRODUCTION OPS
11 INPUT 2 = <TRIGGER> FLUIDIC OPS
12 INPUT 3 = <TRIGGER> FLT CLEAR & REF
13 INPUT 4 = <DISABLED>
if NOT faulted
14 SETUP A SETUP C I/O TEST
15 SCREEN SCREEN SCREEN
----- Displays the Controller Module Status ........ D D D
----- Display/change the aux out 1 setting ........... D D C
----- Display/change the aux out 2 setting ........... D D C
----- Display/change the output 1 setting ............ D D C
----- Display/change the output 2 setting ............ D D C
----- Display/change the output 3 setting ............ D D C
----- Display/change the output 4 setting ............ D D C
----- Display/change the input CC 1 setting ........ D D C
----- Display/change the input CC 2 setting ........ D D C
----- Display/change the input 1 setting ............... D D C
----- Display/change the input 2 setting ............... D D C
----- Display/change the input 3 setting ............... D D C
----- Display/change the input 4 setting ............... D D C
The following screens are accessible from
this screen based on the system status.
Setup A ................................................................ P P P
Setup C ................................................................ P P P
I/O Test ................................................................ P P P