EasyManua.ls Logo

IVT Greenline HT Plus E - Fine-Tuning Temperature Settings; Warm Weather Heat Curve Fine-Tuning

IVT Greenline HT Plus E
71 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
FOR THE USER
Basic functions - Customer level 1
Fine-tune the temperature setting
The heat curve can also be fi ne-tuned. Fine-tuning means that you offset
the heat curve in parallel. Fine-tuning is done in the menu Temp. fi ne-tune
The diagram for fi ne-tuning shows how the dashed line has been offset
upwards in parallel. This means the heating has been fi ne-tuned in a
positive direction and the heat pump will be instructed to maintain a higher
temperature on the return water at all outdoor temperatures.
Outdoor temperature (ºC)
Return temperature (ºC)
By using the menu dial on the
control panel the fi ne-tuning line
has been moved up so the heat
pump produces more heat.
In warm weather (above +5ºC):
If you are not satisfi ed with the indoor temperature when it is warmer than
+5ºC outdoors, you should offset the curve in the menu Temp. fi ne-tune
This is what to do:
1. Press the Heat button in the initial menu.
2. Turn the menu dial clockwise until you reach the menu Temp. fi ne-tune
3. Press the Adjust button.
4. Turn the menu dial clockwise to increase the heating.
Turn the menu dial anti-clockwise to lower the heating.
(Adjust in small increments, 0.5-1.0 units is usually enough.)
5. Save the new value by pressing the Save button.
Temp. ne-tune
-10° 0,0 10°
Return Adjust

Table of Contents

Other manuals for IVT Greenline HT Plus E

Related product manuals