36
In case you stratified solar storage tank LATENTO XXL should be disposed of, we
kindly ask you to give the solar stratified storage tank LATENTO XXL to a suitable
recycling facility. In addition, we offer you to take back the LATENTO XXL for
recycling if it is delivered free of charge to our address.
13. Troubleshooting and remedy
Storage water not heating
In case of solar power in the collector:
– Check the solar circuit for disturbances
– Check the solar pump for function
– Are the flow and return pipes of the solar heat exchanger
connected correctly?
– Any air in the solar circuit? Bleed via air vent plug
– Check pressure
– Collector sensor placed correctly?
In case of conventional reheating:
– Has the reheating heat exchanger been correctly connected?
– Check the boiler circuit for disturbances
– Check pressure
– Check charging pump for function – trapped air
– Check of regulation. Are heat generators, pumps and temperature
sensors connected correctly?
– Are the temperature sensors positioned at the right
height and functional?
Hot water not heating
Filling level of the storage water sufficient? Possibly top up?
Are flow and return pipes of the domestic water heat exchanger
connected correctly?
Is the storage water warm? (see storage water not heating)
Is the thermal mixing valve properly set?
12. Take back or disposal

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IVT LATENTO XXL Series and is the answer not in the manual?

IVT LATENTO XXL Series Specifications

General IconGeneral
BrandIVT
ModelLATENTO XXL Series
CategoryTank Equipment
LanguageEnglish