Read this manual before use of product
IWAKI
Electromagnetic Metering Pump
EH-E Type
Instruction Manual
T308-3 02/06
( )Country codes
IWAKI CO.,LTD. 6-6 Kanda-Sudacho 2-chome Chiyoda-ku Tokyo 101-8558 Japan
TEL:(81)3 3254 2935 FAX:3 3252 8892(http://www.iwakipumps.jp)
U.S.A. : IWAKI WALCHEM Corporation
Australia : IWAKI Pumps Australia Pty. Ltd.
Singapore : IWAKI Singapore Pte. Ltd.
Indonesia : IWAKI Singapore (Indonesia Branch)
Malaysia : IWAKIm Sdn. Bhd.
Taiwan : IWAKI Pumps Taiwan Co., Ltd.
Thailand : IWAKI (Thailand) Co.,Ltd.
Hong Kong : IWAKI Pumps Co., Ltd.
China : IWAKI Pumps Co., Ltd. (Guangzhou office)
China : IWAKI Pumps Co., Ltd. (Beijing office)
China : IWAKI Pumps (Shanghai) Co., Ltd.
Philippines : IWAKI Chemical Pumps Philippines, Inc.
Korea : IWAKI Korea Co.,Ltd.
TEL : (1)508 429 1440 FAX : 508 429 1386
TEL : (61)2 9899 2411 FAX : 2 9899 2421
TEL : (65)763 2744 FAX : 763 2372
TEL : (62)21 690 6607 FAX : 21 690 6612
TEL : (60)3 7803 8807 FAX : 3 7803 4800
TEL : (886)2 8227 6900 FAX : 2 8227 6818
TEL : (66)2 320 1303 FAX : 2 322 2477
TEL : (852)2 607 1168 FAX : 2 607 1000
TEL : (86)20 8130 0605 FAX : 20 8130 0601
TEL : (86)10 6442 7713 FAX : 10 6442 7712
TEL : (86)21 6272 7502 FAX : 21 6272 6929
TEL : (63)2 888 0245 FAX : 2 843 3096
TEL : (82)2 3474 0523 FAX : 2 3474 0221
Germany : IWAKI EUROPE GmbH
Italy : IWAKI Italia S.R.L.
Denmark : IWAKI Pumper A/S
Sweden : IWAKI Sverige AB
Finland : IWAKI Suomi Oy
Norway : IWAKI Norge AS
France : IWAKI France S.A.
U.K. : IWAKI PUMPS (UK) LTD.
Switzerland: IWAKI (Schweiz) AG
Austria : IWAKI (Austria) GmbH
Holland : IWAKI Holland B.V.
Spain : IWAKI Iberica Pumps, S.A.
Belgium : IWAKI Belgium n.v.
TEL : (49)2154 9254 0 FAX : 2154 1028
TEL : (39)02 990 3931 FAX : 02 990 42888
TEL : (45)48 24 2345 FAX : 48 24 2346
TEL : (46)8 511 72900 FAX : 8 511 72922
TEL : (358)9 2742714 FAX : 9 2742715
TEL : (47)66 81 16 60 FAX : 66 81 16 61
TEL : (33)1 69 63 33 70 FAX : 1 64 49 92 73
TEL : (44)1743 231363 FAX : 1743 366507
TEL : (41)32 3235024 FAX : 32 3226084
TEL : (43)2236 33469 FAX : 2236 33469
TEL : (31)297 241121 FAX : 297 273902
TEL : (34)943 630030 FAX : 943 628799
TEL : (32)1430 7007 FAX : 1430 7008

Questions and Answers

Summary

General Safety Instructions

Safe Handling Guidelines

Provides general advice for safe operation, emphasizing manual review and user understanding.

Safety Symbol Meanings

Explains the specific icons and symbols used to convey warnings and cautions in the manual.

Safety Section

Critical Warnings

Highlights essential safety warnings, including electrical hazards, proper application, and environmental considerations.

Operational Cautions

Details cautions for qualified operators, power supply, running dry, liquid exposure, and ventilation.

Installation and Disposal Cautions

Covers precautions for grounding, leakage breakers, cable safety, site limitations, and pump disposal.

Introduction to the EH-E Pump

Unpacking and Initial Inspection

Guide to checking the product upon receipt and reporting any discrepancies or transit damage.

Understanding Pump Operation

Explains the fundamental working principle of the electromagnetic metering pump.

Key Pump Specifications

Lists essential technical details, including model identification, materials, and electrical ratings.

Control Functions and Modes

Describes manual and external input (analog, digital) operation modes of the pump.

Controller Interface Overview

Details the pump's controller panel, keys, indicators, and display examples.

Dimensional Data for Models

Provides external dimension drawings for various EH-E pump models.

Installation and Setup

Installation Precautions

Important safety and procedural notes to follow before and during pump installation.

Site Selection Criteria

Guidance on choosing an appropriate installation location, considering ambient conditions and access.

Tubing and Connections Guide

Instructions for connecting suction, discharge, and bleeding tubes, including fitting types.

Electrical Wiring Procedures

Steps and safety considerations for correctly wiring the pump's power and control circuits.

Operating the EH-E Metering Pump

Pre-Operation Steps and Bleeding

Essential checks before starting operation and the process for removing air from the pump.

Adjusting Output Capacity

Methods for fine-tuning the pump's discharge capacity using stroke length and rate adjustments.

Operating Modes Explained

Overview of manual, analog, pulse multiply, and pulse dividing operational modes.

Controller Operation and Settings

Detailed steps for configuring and operating the pump via the controller interface.

Maintenance and Troubleshooting

Routine Maintenance Practices

Guidelines for regular upkeep, including diaphragm and valve replacement.

Consumable Part Replacement

Information on identifying and replacing consumable parts like valve sets and diaphragms.

Component Identification

Detailed diagrams and lists of parts for pump head units across different models.

Problem Diagnosis and Solutions

A guide to identifying common pump issues and their corresponding corrective actions.

IWAKI PUMPS EH-E Series Specifications

General IconGeneral
ProtectionOverload protection
Protection RatingIP65
SeriesEH-E Series
TypeElectromagnetic Diaphragm Pump
Stroke LengthAdjustable
Materials (Pump Head)SUS316
Materials (Diaphragm)PTFE
Materials (Wetted Parts)SUS316, PTFE, FKM
Power Supply100 to 240 VAC, 50/60 Hz
ControlManual or External Signal
Liquid Temperature Range0 to 50°C
Ambient Temperature Range0 to 40°C
Motor OutputVaries by model
Port SizeVaries by model