EasyManua.ls Logo

IWAKI PUMPS MX Series - User Manual

IWAKI PUMPS MX Series
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Read this manual before use of product
Instruction Manual
(Asia Edition)
IWAKI Magnetic Drive Pump
MX Series (MX-250/-505)
T452-8 '15/07
http://www.iwakipumps.jp
IWAKI CO.,LTD. 6-6 Kanda-Sudacho 2-chome Chiyoda-ku Tokyo 101-8558 Japan
TEL: +81 3 3254 2935 FAX: +81 3 3252 8892
European ofce
/ IWAKI Europe GmbH
TEL: +49 2154 9254 0 FAX: +49 2154 9254 48
Norway
/ IWAKI Norge AS
TEL: +47 23 38 49 00 FAX: +47 23 38 49 01
Australia
/ IWAKI Pumps Australia Pty Ltd.
TEL: +61 2 9899 2411 FAX: +61 2 9899 2421
Germany
/ IWAKI Europe GmbH
TEL: +49 2154 9254 50 FAX: +49 2154 9254 55
Sweden
/ IWAKI Sverige AB
TEL: +46 8 511 72900 FAX: +46 8 511 72922
China (Hong Kong)
/ IWAKI Pumps Co., Ltd.
TEL: +852 2607 1168 FAX: +852 2607 1000
Holland
/ IWAKI Europe GmbH (Netherlands Branch)
TEL: +31 74 2420011 FAX: +49 2154 9254 48
U.K.
/ IWAKI Pumps (U.K.) LTD.
TEL: +44 1743 231363 FAX: +44 1743 366507
China (Guangzhou) / GFTZ IWAKI Engineering & Trading Co., Ltd.
TEL: +86 20 84350603 FAX: +86 20 84359181
Italy
/ IWAKI Europe GmbH (Italy Branch)
TEL: +39 0444 371115 FAX: +39 0444 335350
U.S.A.
/ IWAKI America Inc.
TEL: +1 508 429 1440 FAX: +1 508 429 1386
China
/ IWAKI Pumps (Shanghai) Co., Ltd.
TEL: +86 21 6272 7502 FAX: +86 21 6272 6929
Spain
/ IWAKI Europe GmbH (Spain Branch)
TEL: +34 93 37 70 198 FAX: +34 93 47 40 991
Argentina
/ IWAKI America Inc. (Argentina Branch)
TEL: +54 11 4745 4116
Korea
/ IWAKI Korea Co., Ltd.
TEL: +82 2 2630 4800 FAX: +82 2 2630 4801
Belgium
/ IWAKI Belgium N.V.
TEL: +32 13 670200 FAX: FAX: +32 13 672030
Singapore
/ IWAKI Singapore Pte Ltd.
TEL: +65 6316 2028 FAX: +65 6316 3221
Taiwan
/ IWAKI Pumps Taiwan Co., Ltd.
TEL: +886 2 8227 6900 FAX: +886 2 8227 6818
Denmark
/ IWAKI Nordic A/S
TEL: +45 48 242345 FAX: +45 48 242346
Indonesia
/ IWAKI Singapore (Indonesia Branch)
TEL: +62 21 6906606 FAX: +62 21 6906612
Thailand
/ IWAKI (Thailand) Co., Ltd.
TEL: +66 2 322 2471 FAX: +66 2 322 2477
Finland
/ IWAKI Suomi Oy
TEL: +358 9 2745810 FAX: +358 9 2742715
Malaysia
/ IWAKIm SDN. BHD.
TEL: +60 3 7803 8807 FAX: +60 3 7803 4800
Vietnam
/ IWAKI Pumps Vietnam Co., Ltd.
TEL: +84 613 933456 FAX: +84 613 933399
France
/ IWAKI France S.A.
TEL: +33 1 69 63 33 70 FAX: +33 1 64 49 92 73

Questions and Answers

  • P
    Peggy RobertsonAug 1, 2025
    What to do if the discharge capacity of my IWAKI PUMPS MX is too low?
    • M
      Misty GarciaAug 1, 2025
      If the discharge capacity is too low, several factors could be responsible: * The strainer may be clogged with foreign matter: Remove the foreign matter. * There could be an air pocket in the suction line: Check and correct the suction line. * Foreign matter may be clogging the impeller inlet: Remove the foreign matter. * Air may be entering from a suction line or sealing surface: Check the suction line connections and retighten if needed. * The discharge line may be clogged with foreign matter: Remove foreign matter or scale from the pump/piping. * There may be resistance, such as an air pocket in the suction line: Check for arched pipework. * The actual head may be too high, or pipe resistance may be too large: Check the actual head and pipe resistance.
  • E
    Erica CameronAug 5, 2025
    Why is my IWAKI PUMPS Water Pump motor overheating?
    • I
      Ian AdamsAug 5, 2025
      The motor may be overheating due to several reasons: * Low power voltage: Check the voltage or frequency. * Overload: Check the specific gravity and viscosity of the liquid. * Insufficient ventilation: Ensure good ventilation around the motor.
  • C
    Christina JohnstonAug 9, 2025
    What to do if my IWAKI PUMPS Water Pump is vibrating?
    • P
      pvalenzuelaAug 9, 2025
      If your pump is vibrating, consider the following potential causes: * Poor foundation: Reinstall the pump. * Loose mounting bolts: Retighten the bolts. * Cavitation: Remove the cause of cavitation. * Worn or melted pump bearing: Replace as necessary. * Broken magnet capsule or spindle: Replace as necessary. * Upset dynamic balance of drive magnet: Remove the cause. * The rotating part hits against other parts: Replace as necessary. * Worn motor bearing: Replace bearing or motor.
  • M
    Matthew HarrisAug 14, 2025
    What to do if my IWAKI PUMPS MX pressure drops sharply after starting?
    • J
      Jason MccoyAug 14, 2025
      If the pressure drops sharply after starting when you open a discharge valve, check these: * Air ingress: Ensure suction line connections are completely sealed to prevent air from entering. * Magnet coupling: Check the amperage to see if the motor is overloaded. * Impeller or magnet capsule: Check if foreign matters do not lock the impeller or magnet capsule. * Voltage: Check if voltage is normal.
  • D
    David JamesAug 17, 2025
    What to do if my IWAKI PUMPS Water Pump cannot discharge liquid?
    • B
      Brooke AllenAug 18, 2025
      If the pump isn't discharging liquid: * Check the priming liquid level: If it's too low, stop the pump, prime it, and then resume operation. * Inspect the foot valve: If it's clogged with foreign matter, clean both the foot valve and its seat.
  • G
    Glenn SmithAug 22, 2025
    Why is the discharge capacity of my IWAKI PUMPS MX Water Pump rapidly reducing?
    • J
      Jason VelezAug 23, 2025
      If the discharge capacity is rapidly reducing, it may be because a suction line is clogged with foreign matter. Remove any foreign matter to resolve this issue.
  • K
    Kristen JonesAug 27, 2025
    Why is the pressure low and vacuum very low in my IWAKI PUMPS Water Pump?
    • K
      Kevin BellAug 27, 2025
      If the pressure is low and the vacuum is very low, it's possible that the motor is rotating in reverse. To correct this, interchange the motor wiring.

Summary

Important Instructions

Safe Handling Guidance

Guidance on safe pump operation and product handling.

Symbol Interpretation

Explains warning and caution symbols used in the manual.

Export Restrictions

Information regarding technical data export control regulations.

Safety Instructions

General Safety Precautions

Essential safety measures for pump operation and maintenance.

Handling, Lifting, and Hazard Safety

Safety guidelines for lifting, handling, and operating the pump safely.

Environmental, Personnel, and Electrical Safety

Safety rules for personnel, environment, electrical connections, and pump disposal.

Outline

Product Identification and Specifications

Details on model code, specifications, and performance of the pump.

Dimensional Data and Part Names

Physical dimensions, part identification, and diagrams of the pump.

Pump Overview

A general overview of the pump's main parts and their functions.

Installation

Pre-Installation Procedures and Safety

Crucial steps and precautions before installing the pump.

Pipework, Foundation, and Location

Guidance on pump placement, piping configuration, foundation, and connections.

Piping Stress, Suction, Discharge, and Wiring

Technical requirements for piping, suction/discharge lines, and electrical wiring.

Operation

Operational Precautions and Checks

Safety guidelines and precautions for operating the pump correctly.

Pre-Operation and Starting Procedures

Steps for starting the pump and its initial operation.

Stopping Procedures and Storage

Steps for safely stopping the pump and considerations for storage.

Maintenance

Troubleshooting and Problem Resolution

Guidance to identify and resolve common pump problems and their causes.

Maintenance, Inspection, and Wear Limits

Scheduled checks, inspections, and wear limits for pump components.

Spare Parts and Dismantling;Assembly

List of spare parts and instructions for pump disassembly and assembly.

IWAKI PUMPS MX Series Specifications

General IconGeneral
Frequency50/60 Hz
SeriesMX
Max. Flow60 L/min
Capacity60 L/min
Max. Head16 m
Head16 m
Voltage200V, 220V, 230V; 380V, 400V, 415V
Liquid TemperatureUp to 90°C