14
Inside Masonry Chimney, Vertical
Installation
The wood stove must be installed in accordance with the
applicable local laws or the CAN/CSA-B365, NFPA211 (USA)
norms regarding the installation of chimney. Follow the chimney
manufacturer’s instructions.
The masonry chimney must have a certified stainless steel
sleeve inside covering up all the chimney height. The sleeve
must be at the same diameter as the flue collar. The connection
must be tight and sealed to avoid fume to go indoor.
To pass into a wall between the stove and the masonry chimney,
installation methods have been set to prevent fire. Contact your
local authority to find the latest information in terms of
construction standards.
To install a stove with a chimney serving a masonry fireplace,
you must have a certified stainless steel sleeve inside covering
up all the chimney height. The sleeve must have the same
diameter as the flue collar. The connection must be tight and
sealed to avoid fume to go indoor. Don’t forget to add an opening
for sweeping.
Outside Vertical Installation
The wood stove must be installed in accordance with the
applicable local laws or the CAN/CSA-B365, NFPA211 (USA)
norms. Regarding the installation of chimney, follow the chimney
manufacturer’s instructions.
To pass into a wall between the stove and the masonry chimney,
the installation method has been set to prevent fire. Contact your
local authority to find the latest information in terms of
construction standards.