REV 7-16-201211
Troubleshooting: !DISCONNECT POWER BEFORE SERVICING OR TROUBLESHOOTING!
Problem Possible cause Solution
Breaker inside fuse panel is not in the on position. Turn breaker on.
No power to machine. Check incomin
e.
Loose connection. Check incomin
power connection.
Is the incoming power at 120V? Check voltage and monitor while machine runs.
Low voltage can cause erratic behavior.
Are any of the machines wires worn through or connections
not making contact?
Inspect wiring and connections. Look for sharp
bends in wires and places where wire is against
the metal chassis.
Inadequate wire size ran to machine. Call electrician and install proper wire size for
electrical service versus len
th or run.
Wrong size breaker. Install correct breaker (only if wire size is
ade
.
Inadequate wire size ran to machine. Call electrician and install proper wire size for
electrical service versus len
th or run.
Motor brushes ma
be bad or too short. Replace motor brushes.
Vac hose clo
ed? Clean debris from vac hose.
Filter bags need cleaned or dirt chamber needs emptied? Shake or clean filter bags or replace and empty
lower dirt chamber.
Vac hose is split? Replace/repair vac hose.
Cleanout door
askets torn or worn? Replace
askets.
Vac motor gaskets are worn or motor is not tight against. Inspect/replace gaskets and assure motor is
ti
ainst them.
Dual vac hose unit, both hoses are being used. When both hoses are being used, suction will
be lower. Double check all 3 motors are
workin
however.
Lower chamber cap plugs/mounting hole covers have
ed out?
Open lower chamber and inspect plugs, order
new if needed.
Cleanout door
askets torn or worn? Replace
askets.
One of the vac motors is not working? Check line motor fuse and replace. Replace
motor if necessar
.
Unit keeps tripping
breaker.
Fuses for vac motors keep
blowing.
Lack of vacuum suction.
Unit is not powered.
Machine is behaving