For Your Safe Flight Page 45
2.
Flight
Fuel USED shown by EDM
(total tank - REM) Actual fuel used by topping tanks
1
2
3
Total Œ
2. Total Œ the EDM fuel used and the actual fuel used.
3. Record the current K factor here Ž____________________ and in
the table below.
4. Calculate the New K Factor as follows:
New K Factor = (ŒEDM fuel used) x (ŽCurrent K factor)
(actual fuel used)
New K Factor = (Œ ) x (Ž )
( )
Every time you fine tune the K factor, record the measurements here:
Date
ŒEDM
fuel used
actual
fuel used
ŽCurrent K
factor
New K factor
= ŒxŽ/
Pilot’s
initials
Fuel Flow Option Programming Procedure
Setting the K factor
This procedure is different than for setting other parameters. Place the
select switch in the FF position. If you haven’t already done so, start the
pilot programming procedure, simultaneously hold the STEP and LF
buttons for five seconds. You will see the word PROGRAM for two
seconds.
1. Tap STEP button to advance to the KF-SET screen 29.00=KF
2. Hold both the STEP and LF buttons simultaneously for five seconds.
First digit flashes (shown here as a larger digit only for illustration
purposes): 29.00