Telephone dialer TD-101 / TD-101W - 16 - MDJ512 10 Telephone dialer TD-101 / TD-101W - 9 - MDJ512 10
9. Trouble shooting
It is impossible to stop the dialing function with the Ekey even if it is enabled in the
installer mode. Check if either trigger input IN1 nor IN2 is active (especially if you changed the
trigger input logic to a normally closed contact). Additionally, remember that communication with
the monitoring station can not be stopped until it is finished.
Reaction of the dialer is opposite to what you expect - no reaction when trigger inputs are
activated and the dialer starts to work after inputs are deactivated. In this case the trigger input
logic incorrectly (see item 8.4.).
Dialer does not work when you press the emergency key
F- check that voice message no.
2 was recorded and that there is a telephone number stored in memory
Mem3 or Mem4.
Remember that the emergency function of the
F key can be disabled in the installer mode (see
item 8.11.).
Dialer does not work after any kind of triggering - check that it is not in the user or installer
mode (green and yellow LEDs must be off). Press the
Ekey to get back to the stand by mode.
Check if the TD-101 is powered correctly (press the
Ekey and you should hear a beep). Check
also, if the voice messages are recorded and that the telephone numbers are stored in
corresponding memories (see chapter 6).
It is impossible to enter the user or installer mode - it can be entered only if the dialer is not
dialing (red LED must be off). Wait until the dialing is finished or try to stop the dialing with the
Ekey (if stop has been enabled in the installer level).
You need to temporarily switch the dialer off - for example if the device that controls the dialer
triggers is malfunctioning. In such a case enter the user mode with your user code (the green LED
will be switched on), the TD-101 will be disabled. Remember that the user mode can only be
entered in the moment when the dialer is not calling (red LED must be off). Do not forget to switch
the dialer back to stand by (pressing its
Ekey), after the malfunction is repaired
9.1. Emergency reset
In the event, that you forget your user or installer code (or for some other reason), it is possible to
completely reset all parameters of the TD-101. To do this:
disconnect the power and wait 1 minute
reconnect the power (red LED turns on) enter
B
(within
10 seconds after the power is reconnected)
This procedure resets the factory default settings (UC=1234, IC=1010), all phone numbers and remote
controls (TD-101W only) will be deleted. All the optional functions and parameters will be set to the
factory default setting (see table on page 18 for details).