16
or fall off,
Restart the system after returning to normal .
If cannot solve the problem, please contact with the local agent or call 4008876858.
E5
停针信号异常
The needle stop position signal
abnormal
请关闭系统电源,检查电机停针信号接头是否松动或脱落,将其恢复正常后重启系
统。
上述如仍无法解决请联系当地服务商或拨打 4008876858
Please turn off the machine, then check the motor needle position signal plug connection
loose or not, try factory reset,
Restart the system after returning to normal .
If cannot solve the problem, please contact with the local agent or call 4008876858.
E6
压脚保护功能开启
Presser foot safety switch ON
请检查压脚是否推回到正确位置;
仍无法解决需要临时使用请将 P57 项参数里的 1 改为 0 即可;
上述如仍无法解决请联系当地服务商或拨打 4008876858
Please check whether the presser foot back to the correct position or not ,
If still cant solve the problem, then change value1to 0 in parameter P57.
If cannot solve the problem, please contact with the local agent or call 4008876858.
E7
缝台保护功能开启
Sewing plate safety switch ON
请检查缝台是否推回到正确位置;
仍无法解决需要临时使用请将 P58 项参数里的 1 改为 0 即可;上述如仍无法解决请
联系当地服务商或拨打 4008876858
Please check whether the sewing plate back to the correct position or not ;
If still cant solve the problem, then change value 1to 0 in parameter P58 .
If cannot solve the problem, please contact with the local agent or call 4008876858.
E8
针杆护罩保护功能开启
Needle bar cover safety
switch ON
请检查针杆护罩是否放回到正确位置;
仍无法解决需要临时使用请将 P59 项参数里的 1 改为 0 即可;上述如仍无法解决请
联系当地服务商或拨打 4008876858
Please check whether the needle bar back to the correct position or not ,
If still cant solve the problem, then change value 1to 0 in parameter P59.
If cannot solve the problem, please contact with the local agent or call 4008876858.
E9
脚踏板连接异常
Pedal connection abnormal
请检查脚踏板插头是否连接控制箱或者松动;
上述如仍无法解决请联系当地服务商或拨打 4008876858
Please check whether the pedal plug is connecting with control box or not ,or loosening .
Check if the connection connects the electronic control.
If cannot solve the problem, please contact with the local agent or call 4008876858.
E10
硬件过流
Hardware over-current
请检查供电电压是否正常;
请尝试恢复出厂设置或将电源重启;
上述如仍无法解决请联系当地服务商或拨打 4008876858
Please check whether the voltage is normal or not;
Please try to do factory reset or restart;
If cannot solve the problem, please contact with the local agent or call 4008876858.
E11
停机时过压
Stop over-voltage
请检查供电电压是否正常;
请尝试恢复出厂设置或将电源重启;
上述如仍无法解决请联系当地服务商或拨打 4008876858
Please check whether the voltage is normal or not;
Please try to do factory reset or restart;
If cannot solve the problem, please contact with the local agent or call 4008876858.
E12
系统欠电压
System under-voltage
请检查供电电压是否正常;
请尝试恢复出厂设置或将电源重启;
上述如仍无法解决请联系当地服务商或拨打 4008876858
Please check whether the voltage is normal or not;
Please try to do factory reset or restart;
If cannot solve the problem, please contact with the local agent or call 4008876858.
E13
制动回路异常
Brake circuit fault
请联系当地服务商或拨打 4008876858
Please contact with the local agent or call 4008876858.
E14
参数读写异常
Parameter read-write fault
请尝试关闭电源重启如仍无法解决请联系当地服务商或拨打 4008876858
Please turn off the machine and restart, If cant solve the problem , Please contact with
the local agent or call 4008876858
E15
电机超速保护(暂无)
Motor over-speed protection
(not available)
E16
电机反转(暂无)
Motor reversal (not available)
请恢复出厂设置;上述如仍无法解决请联系当地服务商或拨打 4008876858
Please try factory reset, If cant solve the problem , Please contact with the local agent
or call 4008876858
E17 运行时过压(暂无)