43
I TROUB LES H OOTI NG (please also see the chapter on “Warning Messages”)
PROBLE M PROBAB LE CAUSE SOLUTI ON
Dirty Water Filters clogged or blocked Clean or replace the filters
Insufficient water treatment See the chapter on "Water
High content of solids in the Treatment”
water
Improper maintenance See the instructions regarding
Maintenance
Excessive water Leak in the feed or drain lines, Repair the leak
consumption or at joints
Excessive evaporation and/or Use the spa cover
water overflow Set a lower water temperature set point
Low water flow rate Water level low Fill to the level mark
from the hydromassage nozzles on the skimmer
Filters clogged or blocked Clean or replace the filters
Adjustable jets partially Open the jets
closed
Suction or drain pipes
*
partially clogged
Operating speed of pumps
*
too low
Pump gaskets worn or
*
damaged
Voltage too low Contact an electrician or
the electric power utility
No water flow No power Move the main switch
to the O N position
Pump(s) off Press the button
Motor(s) not connected Check the motor(s)'s
electrical connections
Main switch turned off Turn on the switch
Residual current operated circuit breaker Reset the RCCB
(RC C B) has tripped
Pump(s) or motor(s) faulty
*