Laser Sand Filter System
Owners Manual and Installation Guide
Congratulations! You have purchased one of the most user-friendly pool
filter systems available. Ideal for an above ground pool or in-ground
vinyl liner pool, this filter system will provide you with many years of
pool enjoyment. This step-by-step installation and maintenance guide
will provide the necessary information for you to install your new pool
system and easily maintain the equipment.
ATL160C, L160C
& AQUAMAX 160C
ATL190C & L190C
ATL192C, L192C
& AQUAMAX 200C
ATL225C, L225C
& AQUAMAX 225C
ATL250C, L250C
& AQUAMAX 250C
FLOW RATE
(US GPM/sq ft)
FILTER RATE
(US GPM)
SAND REQ'D
(POUNDS)
FILTER
MODEL
20.0
20.0
20.0
20.0
20.0
27
37
37
53
66
140
200
200
250
350
MAXIMUM
PRESSURE (PSI)
35
35
50
50
50
Before installation be sure to read all instructions and warnings carefully.
Refer to product label(s) for additional operation instruction and specifications.
INSPECTION
Examine the equipment when received. Notify your dealer or carrier of any
damage or missing parts. Verify that equipment is of size and model specified.
IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions
should always be followed, including the following:
RISK OF SUCTION ENTRAPMENT
HAZARD WHICH, IF NOT AVOIDED,
MAY RESULT IN SERIOUS INJURY OR DEATH.
Pumps can quickly generate high suction, which poses the risk of entrap-
ment if improperly connected to suction outlets. Disembowelment, entrap-
ment, or drowning is possible when body parts or hair contact damaged,
cracked, missing, or unsecured drain covers and suction outlets. Pumps
and fittings shall be installed in accordance with the latest NSPI or
IAF standards, CPSC guidelines, and national, state and local codes,
to minimize this risk. Some of those requirements are as follows. Always
consult the latest regulations to ensure that your installation meets the nec-
essary requirements to minimize suction entrapment.
1. All fully submerged Suction Outlet Covers shall be listed to
ANSI/ASME A112.19.8 standard.
2. Do not use a pump in an installation where there is only one fully
submerged single suction outlet.
3. If main drains are installed in your pool, there must be a minimum
of two for each pumping system, and each drain must include a Listed
Suction Outlet Cover. Wading pools may have additional requirements
to minimize entrapment hazards.
4. Skimmers may supply 100% of the required flow to the pump, and
must be vented to atmosphere. A skimmer is not considered a sec-
ond main drain.
5. When two suction outlets are used, the maximum system flow rate
shall not exceed the rating of any one of the listed suction outlet
covers installed. When more than two are used, the sum of the rat-
ings shall be at least twice the maximum system flow rate.
6. Each Suction Outlet Cover shall be separated by a minimum of
three feet (3’), measured from center of suction pipes.
7. Avoid installing check valves. If check valves must be used, ensure
that the installation conforms to applicable standards.
8. Never use the pool or spa if a Suction Outlet Cover is damaged,
cracked, missing, or not securely attached. Suction outlet cover must
be attached with stainless steel screws supplied with the cover. If
screws are lost, order replacement parts from your supplier.
NOTE: For the latest NSPI or IAF Standards, contact the Association of
Pool and Spa Professionals (APSP) at www.theapsp.org or (703) 838-0083,
ext. 301. For the latest Consumer Product Safety Commission (CPSC)
Guidelines, contact the CPSC at www.cpsc.gov or (301) 504-7923. “Guide-
lines for Entrapment Hazards: Making Pools and Spas Safer” can be viewed
at www.cpsc.gov/cpscpub/pubs/363.pdf
WARNING
!
221666072077
To reduce risk of injury, do not permit
children to use this product unless they are
closely supervised at all times.
(For cord & plug connected units) Risk
of Electric Shock. Connect only to a
grounding type receptacle protected by a ground-fault circuit-interrupter
(
GFCI). Contact a qualified electrician if you cannot verify that the recep-
tacle is protected by a
GFCI.
(For cord & plug connected units) Do
not bury cord. Locate cord to minimize abuse
from lawn mowers, hedge trimmers and other equipment.
(For cord & plug connected units) To
reduce the risk of electric shock; if the pump
cord is damaged or appears to be damaged, replace it immediately with the
same type of cord which is available from your local dealer. The new cord
must be installed by a qualified electrician. Inspect the cord annually.
(For hot tub and spa pumps) Do not install
within an outer enclosure or beneath the skirt
of the hot tub or spa, unless so marked.
(For cord & plug connected units) To
reduce the risk of electric shock, do not use
an extension cord to connect unit to electric supply; provide a properly lo-
cated outlet.
Locate the system at least five feet
(1.5M) from the pool to prevent it being used
as a means of access to the pool by young children. (See ANSI/NSPI-8 1996
“Model Barrier Code For Residential Swimming Pools, Spas and Hot Tubs”).
Your filter is a pressure vessel and should
never be serviced while under pressure. Al-
ways shut off pump to relieve the pressure in the filter prior to servicing the unit.
For Canada only: The motor of the filter
pump for above-ground pools is equipped
with a splash cover and a 25 foot three conductor cord ending with a three-pin
grounding plug and must be connected only to a grounding type receptacle
protected by a ground fault circuit interrupter (GFCI).
(For pumps with a 25 ft. (7.62m) cord). This
pump is for use with storable pools only. Do
not use with permanently installed pools. A storable pool is constructed so
that it may be readily disassembled for storage and reassembled to its origi-
nal integrity. A permanently installed pool is constructed in or on the ground or
in a building such that it cannot be readily disassembled for storage.
(For pumps with a 3 ft. (.91 m) cord). This
pump is for use with permanently installed
pools and may also be used with tubs and spas if so marked. Do not use with
storable pools. A permanently installed pool is constructed in or on the ground
or in a building such that it cannot be readily disassembled for storage. A
storable pool is constructed so that it may be readily disassembled for storage
and reassembled to its original integrity.
WARNING
!
WARNING
!
WARNING
!
WARNING
!
WARNING
!
WARNING
!
WARNING
!
WARNING
!
WARNING
!
CAUTION
!
CAUTION
!
Question and Answer IconNeed help?

Do you have a question about the Jacuzzi ATL160C and is the answer not in the manual?

Jacuzzi ATL160C Specifications

General IconGeneral
ModelATL160C
TypeCartridge Filter
Flow Rate160 GPM
Filter Area160 sq ft
Max Working Pressure50 psi
Inlet/Outlet Size2 inch
Cartridge MaterialPleated Polyester

Summary

IMPORTANT SAFETY INSTRUCTIONS

Risk of Suction Entrapment Hazard

Details suction entrapment risks, requiring compliance with NSPI/IAF standards and CPSC guidelines to prevent injury or death.

General Safety Warnings and Precautions

Covers crucial safety advice including child supervision, electrical shock prevention, cord safety, and proper unit placement to avoid hazards.

OPERATION AND INSTALLATION INSTRUCTIONS

Filter Operation Modes

Explains the functions of the dial valve positions: Filter, Backwash, Drain, Whirlpool, Winterize, Rinse, and Test for optimal system operation.

Filter Sand Specifications

Outlines requirements for filter sand, including grade, composition, size, and uniformity coefficient for effective filtration.

Installation Location Considerations

Provides guidance on selecting a suitable location for the filter system, considering proximity to the pool, ventilation, drainage, and accessibility.

SYSTEM ASSEMBLY AND INSTALLATION

Sand Fill Cover and Valve Installation

Details procedures for filling the tank with sand, installing the dial valve, and ensuring proper alignment and sealing for the system.

Plumbing and Electrical Connections

Guides users on connecting plumbing lines and making electrical connections, emphasizing safety precautions and proper wiring practices.

System Start-Up Procedures

Outlines the steps for priming the pump and initiating the first filtration cycle to ensure correct system operation.

MAINTENANCE AND OPERATION

Winterizing the Filter System

Provides instructions for preparing the filter system for winter, including draining the tank and pump to prevent damage from freezing.

Cleaning the Pump Strainer

Details the process for safely cleaning the pump strainer basket to maintain optimal water flow and prevent debris buildup.

Backwashing the Filter

Explains how to perform backwashing to clean the sand bed and maintain filter efficiency, including pressure monitoring.

Water Chemistry Importance

Highlights the necessity of maintaining proper water chemistry for pool sanitation, clarity, and equipment longevity.

TROUBLESHOOTING AND WARRANTY

Common Filter Problems and Solutions

Lists common issues like sand backflow, inadequate filtering, leaks, and pressure problems with their potential causes and fixes.

Jacuzzi Limited Warranty and Claims

Outlines the 36-month warranty for Jacuzzi pool products, coverage exceptions, and the procedure for making a warranty claim.

FILTER SYSTEM PARTS BREAKDOWN

Parts Identification

Provides a detailed breakdown of filter system components with part numbers for Laser L160C, L190C, L192C, L225C, and L250C models.

Dial Valve Repair Parts

Lists specific parts available for repairing the 7-position dial valve, including kits and components.