Jacuzzi lodge S Specifications

General IconGeneral
Voltage240V
Shell MaterialAcrylic
Frame MaterialWood
InsulationFull Foam
Pump2 HP
Warranty5 years

Summary

Warnings

Safe Hot Tub Operation

Ensure user awareness of safe operation, water quality checks, and proper chemical usage.

Installation Preparations

Pre-Installation Checks

Verify required components like filling system, drain, water softener, and electrical connections.

Transport and Initial Inspection

Handle hot tub carefully during transport and inspect packaging and components upon arrival.

Hot Tub Positioning

Site Selection and Sun Protection

Choose a suitable base and protect the hot tub from prolonged sun exposure to prevent material damage.

Connections and Safety

Plumbing and Electrical Connections

Connect plumbing to mains and drain, and ensure electrical connections meet standards and are safely installed.

Installer Responsibilities and Disclaimers

Installer is responsible for safe electrical installation; Jacuzzi denies liability for non-compliance or unauthorized work.

Electricity Consumption Management

Activating Consumption Limiter

Configure system software via control panel to limit electrical consumption using specific key presses and passwords.

Operation Checks and First Start-up

Pre-Operation Checks

Ensure filter cartridge is present, drain valve is closed, and all hydromassage intakes are open before filling.

Filling and Powering On

Fill the hot tub to cover the highest nozzles and turn on the all-pole circuit breaker to start the system.

Panel Installation

Front and Side Panel Attachment

Refer to corresponding drawings for the correct installation of front and side panels.

Control Panel Operation

Function Management Overview

All hot tub functions and settings are managed via the control panel, including navigation with Up/Down keys.

Water Temperature Settings

Temperature Unit Conversion

Convert temperature display between Celsius (°C) and Fahrenheit (°F) using control panel key sequences.

Adjusting Water Temperature

Check and adjust the water temperature set point using Up/Down keys, with a specified range and heater shut-off behaviour.

Heater Operation Notes

Notes on heater LED status indicating heating suspension due to consumption limits and information on heating rate.

Smart Winter Mode

Anti-Freeze Protection System

System automatically activates heater and pump to maintain minimum temperature and protect pipes from freezing.

Water Filtering

General Information and Cycles

Water needs filtering for cleanliness; cycles run daily, with some models having a fast "Boost" option.

Setting Filtration Cycles

Set filtering cycle duration and start delay using the 'Light' and 'Up/Down' keys, with factory default settings provided.

Filtering Cycle Management

Suspending Filtering Cycles

Filtering cycles can be suspended by hydromassage, standby mode, or anti-freeze protection, resuming later.

Overheating Protection

Filtering cycles suspend if water temperature exceeds set point by 1°C for 3 hours, resuming when temperature drops.

Clearray System

Clearray™ oxidizes organic substances, reducing the need for chemical treatments.

Water Filtering

Rapid Filtering (Boost)

Activate rapid filtering for intensive use or chemical treatment, lasting 45 minutes, pump runs with Clearray.

Hydromassage Activation

Pump Activation and Speeds

Activate hydromassage pump at low or high speed depending on the model and function, with automatic shut-off.

Blower Activation

Air Compressor Control

Activate the air compressor (blower) for 20 minutes; can be used for aroma therapy with cartridges.

Spotlight Operation

Underwater Light Control

Control the underwater spotlight using the 'Light' key, which stays on for two hours or can be manually turned off.

System Stand-by

Temporary System Shutdown

Suspend all system devices for 60 minutes for routine maintenance without disconnecting power.

Safety Precautions for Stand-by

CAUTION: Disconnect electric power by turning off the all-pole circuit breaker before accessing electronic or rotating parts.

Abnormal Operating Conditions

Alarm Signals Overview

Alarms are indicated on the display with corresponding error codes, persisting if the condition remains.

Specific Alarm Codes

Details specific alarm codes like FLO (flow switch), HOH (high temp), Ho (excessive temp), H2O (low water level), and their solutions.

Temperature Probe and Thermostat Faults

Addresses errors related to defective temperature probes (rPF) and safety thermostat activation (HPF) due to overheating.

Troubleshooting

Dirty Water Issues

Troubleshoot dirty water by checking filter, water treatment, and maintenance, with solutions like cleaning filters or consulting treatment guides.

Excessive Water Consumption

Address excessive water consumption by repairing leaks, using the hot tub cover, or lowering the water temperature set point.

Low Hydromassage Flow

Troubleshoot low hydromassage flow due to low water level, clogged filter, partially closed jets, or pipe blockages.

No Water Flow Issues

Resolve no water flow issues by checking power, pump status, motor connection, main switch, and resetting RCCB.

Noisy Pump and Motor

Address noisy pump and motor by cleaning filters, finding and repairing leaks, or checking motor bearings and impeller.

Motor Start-up Problems

Troubleshoot motor start-up failures related to power, switch status, voltage, breaker trips, connections, or motor windings.

Motor Stopping Issues

Resolve motor stopping issues due to function end, overload, or unsuitable power supply cables.

Blower Operation Issues

Troubleshoot blower non-operation by checking power, button presses, switch status, breaker trips, or faulty motor.