8.1E No Heat Or Not Enough Heat
Symptoms: Circulation pump (heating pump) is turning, panel heat indicator not lit,
panel is not  ashing FL1.
Standard Troubleshooting Approach
Put hot tub in standard
filtration mode (page 21).
Set temperature high
enough to initiate a heat
call. Remove power to hot
tub then plug in a spare
control panel. Turn power
on. Does indicator work
now?
Replace control panel.
No
Ye
s
Call Jacuzzi Premium
Technical Support.