97
1. Unscrew the two thumbscrews on the utility center panel and remove
the panel. Or, on other models the canister is attached to the utility
center panel. Water pump should be OFF.
2. Turn water supply to the lter canister OFF with the valve located
behind the utility center panel (at the top). Refer to the Universal
Docking Center section.
3. Place drip pan below lter housing to catch any spillage.
4. Press the red button on top of the canister to release pressure.
5. Using a spanner wrench (supplied), rotate the lter canister. Remove
the canister containing the lter cartridge.
6. Dump water out of canister and remove the lter cartridge
inside and dispose of properly.
7. Clean the interior of the canister with mild detergent.
Thoroughly rinse and wipe clean.
8. Remove the O-ring from the groove in the canister and
wipe clean. Recoat with petroleum jelly.
9. Replace the O-ring in the groove, making sure it is properly
seated.
10. Install the new lter cartridge in the canister.
11. Replace the canister (hand tighten is normally sucient).
12. If you are using pressurized City Water without the water
pump, make sure to turn OFF the Water Pump Backow
Valve (located next to the water pump). If you are using the water pump to
circulate water, this valve should be ON. (Refer to Universal Docking Center
section Fresh Water Connections)
13. Turn water supply to the canister ON (using the valve behind the utility pan-
el) and turn the pump ON. Open a faucet and check for leaks.
14. Turn the pump OFF. Replace the panel and the two thumbscrews (if equipped).
The secondary (cartridge) water lter supplies water to the refrigerator and the
drinking faucet (if so equipped). This lter is typically located at the utility center.
RV antifreeze and sanitizer will damage the water lter cartridge. The water pu-
Do not allow water in the canister housing to freeze.
Remove the cartridge lter before using anti-freeze to winterize the sys-
tem or chlorine solution to sanitize the system.
Flush lter canister thoroughly before it is put back into service after
winterizing or sanitizing.
For best results replace lter every 6-12 months (or at the beginning of
each camping season).
Do not use carbon cartridges where water is microbiologically unsafe or
of unknown quality.
Maximum operating pressure is 125 psi (8.75 bar).
Maximum water temperature is 125° F (52° C).