48Z-1, 51R-1, 55Z-1, 57C-1 23
Troubleshooting/FAQs
Issue / FAQ Resolution/Answer
Are the old 8040-8065 attachments
compatible?
The pick up geometry has changed to enable compatibility with competitor
attachments. To enable pick up of old attachments the specific hydraulic quick
hitch is required. Contact dealer for more details if required
How is the “follow me home” lights
system activated?
If LED lights are fitted the machine is capable of the follow me home function.
To activate when shutting machine down the work light button on the switch
panel will flash, press to activate for 3 minutes of light
How to I activate continuous auxiliary flow?
Continuous flow button is located on the underside of the right hand joystick
This button has two functions, the active function is set in the setup menu:
1) Latched auxiliary flow
2) Press & hold auxiliary flow
What are the max flow of the
Auxiliary circuits?
The maximum flow for the hydraulic circuits are as follows:
• High flow – 90l/min
• Low flow – 40l/min
What are the auxiliary flow settings when
in Aux 1 double acting mode 1?
Engine Power Band % Max Aux Flow Aux Flow L/min
L1 30% 27
L2 40% 36
L3 50% 45
G1 60% 54
G2 70% 63
G3 80% 72
H 90% 81
H+ 100% 90