5. Select Test In the Test menu, select one of the following:
For Layer 2 Electrical (Copper) Testing:
Ethernet>10/100/1000>Layer 2 Traffic> Terminate.
For Layer 2 Optical Testing:
Ethernet>1GigE Optical>Layer 2 Traffic> Terminate.
For Layer 3 IPv4 Electrical Testing:
Ethernet>10/100/1000>Layer 3 Traffic> IPv4>Terminate.
For Layer 3 IPv4 Optical Testing:
Ethernet>1GigE Optical>Layer 3 Traffic> IPv4>Terminate.
6. Reset to Defaults In the Tools menu, select Reset Test to Defaults. Press OK to continue.
7. Setup Press the SETUP soft key on the top right side of screen. Select the
indicated folders and configure your test as follows. Leave all other
values at default, unless specified in the Work Order.
Interface,
Physical
Layer
Set to same value as Ethernet switch port.
Options only displayed if Auto Negotiate
= Off
For Layer 3 IPv4 testing, configure the following additional settings:
Options displayed after tapping
Source IP Address field.
Options displayed after tapping
Destination IP Address field.
8. View Results Press the RESULTS soft key, to display the Results screen.